Parameter
Dependency:
Only active in the open-loop controlled mode.
See also: r30485
Note
The quadrature-axis voltage and/or direct-axis voltage, filtered by the bandpass, is switched to the commutation angle
or the frequency via the particular gain factor.
The parameter value has the following unit:
Quadrature-axis voltage: rad/V
Direct-axis voltage: (rad/s)/V
r30474
CO: RAILCTRL velocity controller scaling P gain / v_ctrl scal Kp
All objects
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min:
-
Description:
Display and connector output for scaling the proportional gain (Kp) of the velocity controller.
Recommendation:
Recommended BICO interconnection:
CI: p1466 = r30474
p30475
CI: RAILCTRL control word / STW
All objects
Can be changed: T
Data type: Unsigned32 / Integer16
P-Group: Closed-loop control
Not for motor type: -
Min:
-
Description:
Sets the signal source for control word RAILCTRL_STW of the sequence control.
Generally, the value is provided from the higher-level control system using an extended standard telegram.
The significance of the individual bits of the control word is described in parameter r30476.
Dependency:
See also: r30476
NOTICE
It does not make sense to simultaneously select several operating states (e.g. open-loop controlled and closed-loop
controlled). For the case that several operating states are selected via the control word, alarm A53180 is output and
according to the following defined priority, the system changes into one of the selected states:
1. Closed-loop controlled mode
2. Open-loop controlled mode master
3. Open-loop controlled mode previous slave
4. Open-loop controlled mode subsequent slave
It is only possible to transfer the commutation angle set in p30480 via bit 7 of the control word when in the open-loop
controlled mode the master is in the switched-off state.
r30476.0...7
CO/BO: RAILCTRL control word active / STW active
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Closed-loop control
Not for motor type: -
Min:
-
Description:
Display and BICO output for the active control word RAILCTRL_STW.
62
Calculated: -
Dynamic index: -
Unit group: -
Scaling: PERCENT
Max:
-
Calculated: -
Dynamic index: -
Unit group: -
Scaling: -
Max:
-
Calculated: -
Dynamic index: -
Unit group: -
Scaling: -
Max:
-
Function Manual, 09/2019, A5E38120767B
Access level: 3
Function diagram: -
Unit selection: -
Expert list: 1
Factory setting:
-
Access level: 3
Function diagram: 7366
Unit selection: -
Expert list: 1
Factory setting:
0
Access level: 3
Function diagram: 7364, 7366
Unit selection: -
Expert list: 1
Factory setting:
-
RAILCTRL