p30455
RAILCTRL encoder linearization / Encoder linear
All objects
Can be changed: T
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min:
0
Description:
Sets the linearization for the Festo SDAT encoder.
If a non-supported linearization is set, the encoder automatically uses the standard linearization.
p30460
RAILCTRL start of measuring range / Meas range start
All objects
Can be changed: C1(3)
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min:
0.00 [mm]
Description:
Sets the local (referred to the segment) coordinate for the start of the measuring range of the selected encoder.
The measuring range length is set using p30462.
Dependency:
See also: p30453, p30462
Note
The position outside the measuring range is set to zero.
p30461
RAILCTRL start of the primary section / Primary sect start
All objects
Can be changed: C1(3)
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min:
0.00 [mm]
Description:
Sets the local (referred to the segment) coordinate for the start of the primary section.
The primary section length is set using p30463.
Dependency:
Only active in the closed-loop controlled mode.
See also: p30463
p30462
RAILCTRL measuring range length / Meas range length
All objects
Can be changed: C1(3)
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min:
0.01 [mm]
Description:
Sets the length of the measuring range of the selected encoder.
The start of the measuring range is set using p30460.
Dependency:
See also: p30453, p30460
Note
The position outside the measuring range is set to zero.
RAILCTRL
Function Manual, 09/2019, A5E38120767B
Calculated: -
Dynamic index: -
Unit group: -
Scaling: -
Max:
127
Calculated: -
Dynamic index: -
Unit group: -
Scaling: -
Max:
340.28235E36 [mm]
Calculated: -
Dynamic index: -
Unit group: -
Scaling: -
Max:
340.28235E36 [mm]
Calculated: -
Dynamic index: -
Unit group: -
Scaling: -
Max:
340.28235E36 [mm]
Parameter
Access level: 3
Function diagram: -
Unit selection: -
Expert list: 1
Factory setting:
0
Access level: 3
Function diagram: 7361
Unit selection: -
Expert list: 1
Factory setting:
40.00 [mm]
Access level: 3
Function diagram: 7361, 7363
Unit selection: -
Expert list: 1
Factory setting:
50.00 [mm]
Access level: 3
Function diagram: 7361
Unit selection: -
Expert list: 1
Factory setting:
326.00 [mm]
59