Siemens SINAMICS RAILCTRL Function Manual page 70

Rail control
Table of Contents

Advertisement

Parameter
Note
For bit 00:
The configuration mode is active as long as one of the following conditions is fulfilled:
- parameter p30490[0], required to establish communications to the previous Control Unit, is not set.
- the DRIVE-CLiQ cable to the connection partner has not been inserted (Alarm A53163 with fault cause 2).
For bit 03:
- Alarm A53164 with fault cause 2.
For bit 04:
- when the bit is set, the DRIVE-CLiQ connection is interrupted.
- alarm A53164 with fault cause 3.
For bit 05:
- when the bit is set, isochronous operation is established.
- also see parameters r2043.1 and r8843.1 for IF1 or IF2.
IF1: Interface 1
IF2: Interface 2
r30494.0...5
CO/BO: RAILCTRL communication status to the subsequent CU / Status subseq CU
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Closed-loop control
Not for motor type: -
Min:
-
Description:
Display and BICO output for the status of the communication to the subsequent Control Unit.
Bit field:
Bit
00
01
02
03
04
05
Dependency:
See also: r30493
See also: A53163, F53164
Note
For bit 00:
The configuration mode is active as long as one of the following conditions is fulfilled:
- parameter p30490[1], required to establish communications to the subsequent Control Unit, is not set.
- the DRIVE-CLiQ cable to the connection partner has not been inserted (Alarm A53163 with fault cause 2).
For bit 03:
- Alarm A53164 with fault cause 2.
For bit 04:
- for an interrupted DRIVE-CLiQ connection, this bit has a 1 signal.
For bit 05:
- this bit has a 1 signal after establishing isochronous operation.
- also see parameters r2043.1 and r8843.1 for IF1 or IF2.
IF1: Interface 1
IF2: Interface 2
68
Signal name
Wait for configuration
Wait for data transfer
Data being transferred
Checksum error detected
Data package lost
Isochronous operation active
Calculated: -
Dynamic index: -
Unit group: -
Scaling: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Function Manual, 09/2019, A5E38120767B
Access level: 3
Function diagram: -
Unit selection: -
Expert list: 1
Factory setting:
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
RAILCTRL