Downloading The Technology Package - Siemens SINAMICS RAILCTRL Function Manual

Rail control
Table of Contents

Advertisement

4.2.3

Downloading the technology package

In the following, the Technology Extension ABC_OA with version V1.1 is loaded into the device
via STARTER.
Requirements
The following requirements must be met before downloading:
1. A project matching the device is open.
2. The STARTER commissioning tool is in ONLINE mode.
Procedure
To download, proceed as follows:
1. Right-click the drive unit in the project navigator.
2. Click "Select technology packages" in the shortcut menu.
The "Select technology packages" window opens.
3. For the technology package "ABC_OA", set the action "Load to target device"
Figure 4-2
4. Click the "Perform actions" button.
After successfully performing the action, the information "OK" is displayed for the
corresponding "Result" field.
5. If necessary, switch the target device off and on again (POWER ON).
Additional information on the "Select technology package" dialog
For a technology package, the "Version (online)" column is only populated after executing
"Load to target device".