POINT DESCRIPTION
Currently Occupied
Damper fdbk out of range
Damper fdbk Short Alert
Damper Not Mod Alert
Damper Stuck Closed Alrt
Damper Stuck Open Alert
DD IDF High Speed Relay
DD IDF Low Speed Relay
DD IDF Med. Speed Relay
Diff. Dry Bulb Control
Diff. Enthalpy Control
dirty filter alert
Dirty Filter Alerts
Dmpr fdbk Open Cir Alert
Dry Bulb Lockout
DST allowed?
DST currently active
Econ Damper Operational
Econo Actual Position
Economizer Alerts
Economizer Cooling
Economizer Installed?
Economizer Not Cooling
Enthalpy Lockout
Excess Outside Air Alert
Fan Off When Cmded On
Fan On When Cmded Off
Fan On When Occupied
fan status warning alert
fbdh sat locked out
FBDH SST locked out
Filter Status Switch
Fire shutdown fault
Fire Shutdown Switch
FSPDHRLY IDF Test
FSPDLRLY IDF Test
FSPDMRLY IDF Test
FST Open Circuit Alert
FST out of Range Alert
FST Sensor Error
FST Short Circuit Alert
General Status alert
General Status Alerts
General Status fault
General Status Switch
Hardware Failures Alerts
Heat Stage 1 Available
Heat Stage 1 Relay
Heat Stage 2 Available
Heat Stage 2 Relay
HeatDemandLimiting
Heating Failure Alerts
Heating Stage 1 Test
Heating Stage 2 Test
Humidimizer Status
humidity ctrl is active
IAQ Open Circuit Alert
IAQ override enable
IAQ override sw state
IAQ Preoccupancy Purge
IAQ Sensor Error
APPENDIX E — BACNET POINTS LIST
Table Z — BACnet* BV Points List (cont)
POINT ACCESS
UNITS
R/W
R/W
R/W
R/W
R/W
R/W
READ ONLY
READ ONLY
READ ONLY
R/W
R/W
R/W
R/W
R/W
R/W
R/W
READ ONLY
READ ONLY
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
READ ONLY
READ ONLY
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
READ ONLY
READ ONLY
READ ONLY
READ ONLY
R/W
R/W
R/W
R/W
R/W
READ ONLY
R/W
R/W
R/W
R/W
R/W
BACNET
BACNET
OBJECT NAME
occ_status
BV:2008
a_badec1
BV:184
a_shtec1
BV:203
a_dnm
BV:215
a_dnm_sc
BV:216
a_dnm_so
BV:217
fspdhrly
BV:448
fspdlrly
BV:446
fspdmrly
BV:447
dif_db_ena
BV:41
dif_enth_ena
BV:42
a_dfilt
BV:214
filter_alarm
BV:7017
a_opnec1
BV:192
db_lock_out
BV:40
dst_cfg
BV:93
dst_actv
BV:92
damp_good
BV:39
dmpr_err
BV:21
econ_alarm
BV:43
a_t24ewc
BV:226
econo_cfg
BV:131
a_t24enc
BV:224
enth_lock_out
BV:44
a_t24eoa
BV:225
f_idfoff
BV:230
f_idfon
BV:231
occupied_fan
BV:46
a_idfwar
BV:219
fbdsatlo
BV:439
fbdsstlo
BV:440
flt_status
BV:1016
f_fire
BV:242
firedown
BV:112
s_fshrly
BV:464
s_fslrly
BV:462
s_fsmrly
BV:463
a_opnfst
BV:193
a_badfst
BV:185
fst_error
BV:49
a_shtfst
BV:204
a_gensw
BV:244
gens_al
BV:309
f_gensw
BV:265
gen_status
BV:50
hw_al
BV:305
ht1_aval
BV:16
hs1
BV:10
ht2_aval
BV:17
hs2
BV:11
heatdmdLimit
BV:370
heat_al
BV:306
s_heat1
BV:76
s_heat2
BV:77
humz_en
BV:7010
humctrla
BV:423
a_opniaq
BV:194
iaq_override_en
BV:445
iaqoverride_switch
BV:7030
iaqpurge
BV:20
iaq_err
BV:51
168
VALUE
CCN POINT
ID
RANGE
EQUIVALENT
0 to 1
OCCUPIED
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
FSPDHRLY
0 to 1
FSPDLRLY
0 to 1
FSPDMRLY
0 to 1
DIFFBULB
0 to 1
DIFFENTH
0 to 1
0 to 1
FILT_AL
0 to 1
0 to 1
DBLOCK
0 to 1
DST_CFG
0 to 1
DST_ACTV
0 to 1
DAMPGOOD
0 to 1
DAMP_ERR
0 to 1
ECON_AL
0 to 1
0 to 1
ECONO
0 to 1
0 to 1
ENTHLOCK
0 to 1
0 to 1
0 to 1
0 to 1
FANON_OC
0 to 1
0 to 1
FBDSATLO
0 to 1
FBDSSTLO
0 to 1
FILTSTAT
0 to 1
0 to 1
FIREDOWN
0 to 1
S_FSHRLY
0 to 1
S_FSLRLY
0 to 1
S_FSMRLY
0 to 1
0 to 1
0 to 1
FST_ERR
0 to 1
0 to 1
0 to 1
GENS_AL
0 to 1
0 to 1
GENSTAT
0 to 1
HW_AL
0 to 1
HT1_AVAL
0 to 1
HEAT_1
0 to 1
HT2_AVAL
0 to 1
HEAT_2
0 to 1
HDMLMOFF
0 to 1
HEAT_AL
0 to 1
S_HEAT1
0 to 1
S_HEAT2
0 to 1
HUMZ_EN
0 to 1
0 to 1
0 to 1
IAQOVREN
0 to 1
IAQ_OVRS
0 to 1
IAQPURGE
0 to 1
IAQ_ERR