Carrier 48LC Series Controls, Start-Up, Operation And Troubleshooting page 145

Single package rooftop units with systemvu controls version 3.x and puron (r-410a) refrigerant
Table of Contents

Advertisement

APPENDIX D — SYSTEMVU™ CONTROLLER CCN TABLES
TABLE
DISPLAY NAME
OARH Sensor Value
RARH Sensor Value
IAQ Sensor Value
OAQ Sensor Value
OACFM Sensor Value
Equipment Model Number
HW_IO
Equipment Serial Number
(cont)
Application SW Version
VFD1 SW Version
SIOB1 SW Version
Bootloader SW Version
MBB Part Number
MBB Program Part Number
Base Board Serial Number
Zone Sensor Temp Out
ZS1 Temp
ZS2 Temperature
ZS3 Temperature
ZS4 Temperature
ZS5 Temperature
Zone Sensor Humidity Out
ZS1 Humidity
ZS2 Humidity
ZS3 Humidity
ZS4 Humidity
ZS5 Humidity
ZS Override Time Remain
ZS1 Override Time Remain
ZS2 Override Time Remain
ZSENSORS
ZS3 Override Time Remain
ZS4 Override Time Remain
ZS5 Override Time Remain
ZS Setpoint Offset Output
ZS1 Cool Setpoint Offset
ZS2 Cool Setpoint Offset
ZS3 Cool Setpoint Offset
ZS4 Cool Setpoint Offset
ZS5 Cool Setpoint Offset
ZS1 Heat Setpoint Offset
ZS2 Heat Setpoint Offset
ZS3 Heat Setpoint Offset
ZS4 Heat Setpoint Offset
ZS5 Heat Setpoint Offset
Supply Voltage Leg 1
Supply Voltage Leg 2
Supply Voltage Leg 3
Comp A1 Amps Leg 1
Comp A1 Amps Leg 2
Comp A1 Amps Leg 3
Comp A2 Amps Leg 1
USER_INS
Comp A2 Amps Leg 2
Comp A2 Amps Leg 3
Elec. Heat Amps Leg 1
Elec. Heat Amps Leg 2
Elec. Heat Amps Leg 3
Gas Supply Type
Table T — MAINTENANCE TABLES (cont)
0 to 100
0 to 100
xxxx
xxxx
xxx.x
xxxxxxxxxxxxxxxxxx
xxxxxxxxxx
CESR131651-xx-xx
text
SIOB1 SW VERSION-xx-xx
CESR131659-xx-xx
CEPL131117-xx-R
CEPP130644-xx-xx-xx-R
xxxxNxxxxxx
–40 to 245
–40 to 245
–40 to 245
–40 to 245
–40 to 245
–40 to 245
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 600
0 to 600
0 to 600
0 to 600
0 to 600
0 to 600
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
–10 to 10
0 to 700
0 to 700
0 to 700
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 =Natural,
1 = LP
145
RANGE
UNITS
%
%
ppm
ppm
cfm
°F
°F
°F
°F
°F
°F
%
%
%
%
%
%
min
min
min
min
min
min
°F delta
°F delta
°F delta
°F delta
°F delta
°F delta
°F delta
°F delta
°F delta
°F delta
°F delta
volt
volt
volt
amps
amps
amps
amps
amps
amps
amps
amps
amps
WRITE
POINT NAME
STATUS
OARH_LOC
RARH_LOC
IAQ_LOC
OAQ_LOC
OCFM_LOC
EQ_MOD
EQ_SER
FW_CESR
VFD1_SW
SIOB1_SW
BL_CESR
BD_CEPL
BD_CEPP
BD_SER
ZSZT
ZS1ZT
ZS2ZT
ZS3ZT
ZS4ZT
ZS5ZT
ZSSPRH
ZS1ZHUM
ZS2ZHUM
ZS3ZHUM
ZS4ZHUM
ZS5ZHUM
ZSOTR
ZS1OTR
ZS2OTR
ZS3OTR
ZS4OTR
ZS5OTR
ZSSPTO
ZS1CSOFF
ZS2CSOFF
ZS3CSOFF
ZS4CSOFF
ZS5CSOFF
ZS1HSOFF
ZS2HSOFF
ZS3HSOFF
ZS4HSOFF
ZS5HSOFF
L1VOLTS
L2VOLTS
L3VOLTS
CA1L1_A
CA1L2_A
CA1L3_A
CA2L1_A
CA2L2_A
CA2L3_A
EHTL1_A
EHTL2_A
EHTL3_A
GASTYPE

Hide quick links: