Carrier 48LC Series Controls, Start-Up, Operation And Troubleshooting page 103

Single package rooftop units with systemvu controls version 3.x and puron (r-410a) refrigerant
Table of Contents

Advertisement

APPENDIX A — SYSTEMVU™ CONTROLLER DISPLAY
DISPLAY TEXT
NETWORK SETTINGS (cont)
SPACE TEMP AI
SPACE RH AI
ZS SENSOR CFG
ZS1 ADDRESS
ZS2 ADDRESS
ZS3 ADDRESS
ZS4 ADDRESS
ZS5 ADDRESS
ZS POLL RATE
ZS UNIT
ZS FRC UNOC ENBL
ZS FRC UNOC DELAY
ZS TLO CONT ENBL
TLO SET DURING OC
ZS UI MODE
NETWORK CHKLIST
DISPLAY SETTINGS
METRIC DISPLAY
LANGUAGE
CONTRAST ADJUST
PASSWORD ENABLE?
VIEW USER PASSWORD
CHANGE USER PASSWORD
QUICK SETUP CONFIG
TIME
DATE
STARTUP DELAY
UNIT CONTROL TYPE
THERMOSTAT TYPE
DIRTY FILTER TIME
VENT IDF SPEED
HEATING STAGE QTY
ECON INSTALLED?
FREE COOL MAX OAT
FIRE SHUTDOWN SW
QUICK SET CHKLIST
Table B — Settings Main Menu Layout (cont)
EXPANDED TEXT
System Touch AI for SPT
System Touch AI for SPRH
ZS Sensor Configuration
Zone Sensor 1 Address
Zone Sensor 2 Address
Zone Sensor 3 Address
Zone Sensor 4 Address
Zone Sensor 5 Address
Zone Sensor Poll Rate
Zone Sensor Unit
ZS Force Unoccup Enable
ZS Force Unocc wt Delay
ZS TLO Cont Enable
ZS TLO set during occ
Zone sensor UI Mode
NETWORK SETUP CHECKLIST
User Display Configurations
Menu
Metric Display
Display Language Select
LCD Contrast Adjustment
User Password Protection
View User Password Menu
Change User Password Menu
QUICK SETUP CONFIG MENU
Clock Hour and Minute
Current Date
Unit Startup Delay
Unit Control Type
Thermostat Hardware Type
Change Filter Timer
Ventilation Only IDF Spd
Number of Heating Stages
Economizer Installed?
Free Cooling Max OAT
Fire Shutdown Switch
QUICK SETUP CHECKLIST
RANGE
UNITS
0 to 9999
0 to 9999
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
1 to 100
sec
0=degrees F
No
No
No
No
1=Dual Offsets
0=Undone,
1=Perfom,
2=Done
Yes/No
0=English
1 to 10
Enable/Disable
xx:xx
hh.mm
MM/DD/YYYY
10 to 600
sec
0=TSTAT,
1=SPACE SEN,
2=RAT SEN
0=CONV 2C2H,
1=DIGI 2C2H,
2=CONV 3C2H,
3=DIGI 3C2H
4=DIGI 2C2H
0 to 9999
hours
0 to 100
%
0 to 2
Yes/No
0 to 90
°F
0=NORM OPEN,
1=NORM CLSD,
2=NO SWITCH
0=Undone,
1=Perfom,
2=Done
103
DEFAULT
POINT
1
AISTSPT
4
AISTSPRH
255
ZSADDR1
255
ZSADDR2
255
ZSADDR3
255
ZSADDR4
255
ZSADDR5
5
ZSPOLLRT
0=degrees F
ZSUNIT
No
ZSFUNEN
No
ZSFUNWT
No
ZSTLOEN
No
ZSTLSOC
1=Dual Offsets
ZSUIM
0=Undone
CHK_NET
No
DISPUNIT
0=English
LANGUAGE
5
LCD_CONT
Enable
PASS_EBL
0
TIME
0
DATE
30
STARTDLY
0=TSTAT
CTRLTYPE
2=CONV 3C2H
STATTYPE
600
FILTLIFE
50 (sizes 04-06)
67 (sizes 07-12)
53 (sizes 14 or 20)
FSPDVENT
56 (size 17)
52 (size 24)
60 (size 26)
2 (all except below):
0 (50 series without
FIOP heat),
1 (50 series, sizes 04-
06 low or medium
heat),
NUMHSTGS
1 (50 series, sizes
07-14 and low heat),
1 (50 series, sizes
07-12 and medium
heat)
No: no FIOP
ECONO
Yes: FIOP
65
2: no FIOP
FIRE_CFG
0: FIOP
0=Undone
CHK_QUIK

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50lc series

Table of Contents