Procedure for installing the new fan
1
2
3
4
5
12.5
Replacing a power output module (POM)
12.5.1
Safety information
Danger from electrical voltages
May cause death or serious injury
• Before replacing the POM, the AC power supply at the installation location of the device
• The 24 V DC power supply must be interrupted.
SIPLUS HCS4200 PROFINET/PROFIBUS DP
Operating Instructions, 07/2019, A5E35066204A/006
Position the new fan on the device
Insert the two plastic rivets of the fan
Insert sleeve
•
Push in pin
•
Place fan grille on the new fan
Re-insert the four plastic rivets of the fan grille
Insert sleeve
•
Push in pin
•
Plug in 24 V DC connector of the new fan
WARNING
must be de-energized and secured against reconnection.
12.5 Replacing a power output module (POM)
①
.
②
.
③
.
Service and maintenance
197