Article number
Heating power
Number of digital outputs
•
Number of heating elements per
•
output, max.
Output voltage for heating power
•
2nd output voltage for heating pow-
•
er
Power carrying capacity per output,
•
min.
Power carrying capacity per output,
•
max.
–
for heating elements with high
inrush current, max.
Output current for heating power
•
Melting I2t value
•
Design of short-circuit protection
•
per output
Design of overvoltage protection
•
Connection method
Design of electrical connection at
•
output for heating and fan
–
Connectable conductor cross-
sections, solid
–
Connectable conductor cross-
sections, finely stranded with
wire end processing
–
Connectable conductor cross-
sections for AWG cables,
stranded
SIPLUS HCS4200 PROFINET/PROFIBUS DP
Operating Instructions, 07/2019, A5E35066204A/006
6BK1942-2AA00-0AA0
16
1
230 V
40 W; At 230 V AC
1 449 W; At 230 V AC
750 W; At 230 V AC
6.3 A; max.
57 A²·s
Safety fuse 6.3 A
Transil Diode
Connector, 8-pin with ten-
sion spring connection
1x (0.2 ... 10 mm²)
1x (0.25 ... 6 mm²)
1x (24 ... 8)
Technical specifications
13.4 Technical specifications of POM
6BK1942-2CA00-0AA1
12
277 V
60 W; At 230 V AC
3 680 W; At 230 V AC
1 600 W; At 230 V AC
16 A; max.
20 A²·s
Fuse 16 A
Connector, 6-pole with
spring-loaded connection
215