Article number
Setpoint input
Percent
Watts
Heating power
Number of digital outputs
•
Number of heating elements per
•
output, max.
Output voltage for heating power
•
2nd output voltage for heating pow-
•
er
3rd output voltage for heating power 400 V
•
4th output voltage for heating power 480 V
•
5th output voltage for heating power
•
Power carrying capacity per output,
•
min.
Power carrying capacity per output,
•
max.
–
for heating elements with high
inrush current, max.
Output current for heating power
•
Melting I2t value
•
Design of short-circuit protection
•
per output
Design of overvoltage protection
•
Connection method
Design of electrical connection at
•
output for heating and fan
–
Connectable conductor cross-
sections, solid
–
Connectable conductor cross-
sections, finely stranded with
wire end processing
–
Connectable conductor cross-
sections for AWG cables,
stranded
SIPLUS HCS4200 PROFINET/PROFIBUS DP
Operating Instructions, 07/2019, A5E35066204A/006
6BK1942-2DA00-0AA0
Yes
Yes
8
5; Recommended, de-
pends on tolerance of heat-
ing elements
230 V
277 V
400 W; At 230 V AC
4 600 W; At 230 V AC
2 700 W; At 230 V AC
20 A; max.
120 A²·s
Melting fuse 25 A
Transil Diode
Plug, 4-pole, with spring-
loaded connection
1x (0.2 ... 10 mm²)
1x (0.25 ... 6 mm²)
1x (24 ... 8)
Technical specifications
13.4 Technical specifications of POM
6BK1942-2FA00-0AA0
No
12
1
110 V
70 V
45 V
100 W; At 230 V AC
3 680 W; At 230 V AC
1 600 W; At 230 V AC
16 A; max.
20 A²·s
Fuse 16 A
Connector, 6-pole with
spring-loaded connection
221