ADEMCO VistaKey-SK Installation & Setup Manual page 67

Single-door access control starter kit
Hide thumbs Also See for VistaKey-SK:
Table of Contents

Advertisement

008 ZT P RC B IN L
00 _ _ _ _ _ _ _
008 ZONE TYPE
008 Access Point
(01-15)
008 Entry or Exit
Entry
008 PARTITION
008 REPORT CODE
st
nd
1
03 2
12
3C
008 INPUT TYPE
Hardwire
01
008 ZT P RC
IN L
29 2 80
H W 1
3. Exit #93 Menu Mode Programming.
4. The action to be performed on exit can be assigned to either an access group or a
cardholder. To assign the action on exit to an access group, observe the items listed under
a. below. To assign the action on exit to a cardholder, observe the items listed under b.
below.
a. To assign the action on exit to an access group, use the procedures provided in "Setting
Up Access Groups" described earlier in this section. When setting up access groups,
observe the following:
A display appears showing a summary of that zone's
programming. ZT = Zone Type, P = Partition, RC = Report Code,
B = Bell/Aux Relay assignment for zone, IN = the input type of
device, and L = the device's loop number to which the sensor is
connected. Some devices can support more than one zone by
means of individual loops. If the zone is not programmed, the
display appears as shown here.
Press [ ] to continue.
Press 29 for momentary exit.
Press [ ] to accept the entry and continue.
Enter the 2-digit (01-15) door number for the VistaKey.
NOTE: The response to this question must be the address that
3
was set in the VistaKey module for the door (access point) being
programmed.
Press [ ] to continue.
Always press 1 for Exit. Note that this is a standard message
display used for programming access points and that you should
0
never respond with 0 (entry) when defining a momentary exit
zone.
Press [ ] to continue.
Enter the partition number that the access point is assigned to.
2
Press [ ] to continue.
When you are programming for the Momentary Exit function,
the response to this entry does not affect operation.
Press [ ] repeatedly until the INPUT TYPE prompt appears.
Enter the zone input type. In this example, zone 8 is a hardwired
zone.
Press [ ] to continue.
The summary screen for the zone appears.
Press to accept the zone information.
The alarm system control returns to the "ENTER ZONE NO."
prompt. Enter "000" and then press [ ] to exit Zone
Programming.
Section 5 - Programming
5–27