Programming Event/Actions

Event/Actions are used to make something occur (action) when something happens (event).
One example is turning on a light (via a relay) when anyone is allowed to enter (access
grant).
Event/Actions for the VistaKey are set using Event/Action Programming. To reach
event/action programming, enter #93 Menu Mode Programming and press the [0] key
until the following prompt is displayed.
EVENT/ACTION PGM
1=YES 0=NO
Event/Action#
(01-32), 00=quit
• The action only occurs when the above exit event occurs at the
access point selected and the card triggering the event is assigned
to this access group.
• Actions that arm or disarm partitions are only performed if the
VISTA user assigned to the card is assigned to the partitions
selected.
NOTE: When you use action codes 60 (AP Exit Only), 66 (AP Group
Exit Only), or 72 (AP Partition Exit Only), these actions disable the
entry reader at the access point. The reader will remain disabled
until a command is received (via a keypad command or event) to
protect the access point.
Press [ ] to accept the entry.
In response to the exit action entered, the system displays a message
asking for additional information, based on the exit action you
selected. For example, if the exit action selected was 01 (relay on),
the system presents a message asking for a relay number. Respond
to the message and then press [ ] to accept the entry.
The program returns to the "Access Group" prompt so that another
access group may be programmed.
NOTES:
• Users will be assigned to the access group(s) later using the
Performing Access Control Card Functions procedures in Section 6:
User Commands.
• Newly defined access groups must be enabled before they become
active. This enable is performed after leaving #93 Menu Mode
Programming and is described under Enabling Access Groups later
in this section.
Press 1 or 0.
0
If you press 1, the keypad displays the following prompt.
NOTE: Before you enter Event Action Programming, complete the
procedures and worksheet provided in Preparing an Event/Action
Worksheet in this section. The responses should come from your
worksheet.
If you press 0, the alarm system control advances to the Quit Menu
Mode programming prompt.
Enter a number from 01 to 32, from your Event/Actions Worksheet,
01
that corresponds to the event/action to be programmed; or 00 to quit
Event/Action Programming.
Press [ ] to accept the entry.