Mapping Vistakey Zones For Test - ADEMCO VistaKey-SK Installation & Setup Manual

Single-door access control starter kit
Hide thumbs Also See for VistaKey-SK:
Table of Contents

Advertisement

supply. Then, connect the transformer to terminals 1 and 2 of the power supply and
plug the transformer into a 24-hour outlet.
When power is connected, the reader will beep and its red LED should remain on. (If the
LED is blinking yellow, the state of the DSM switch needs to be temporarily reversed. This
may be accomplished by opening the door if closed, or closing the door if opened, until the
testing of this access point is completed as described below.)
3. Re-install the VistaKey module front cover and, if you are installing a VistaKey-SK, close
the door on the VistaKey-SK cabinet.

Mapping VistaKey Zones for Test

To prepare the VistaKey and panel for testing, VistaKey Zones must be mapped into panel
zones. To map VistaKey zones into panel zones, perform the following steps:
1. Enter the #93 Menu Mode Programming mode in the alarm system in accordance with
the procedures provided in your alarm system manuals. The keypad displays:
2. Press 1 for zone programming. The keypad displays:
3. Press 1 for Confirm. The keypad displays:
4. Enter a 3-digit zone number for the access point (e.g., 100).
5. Press the [ ] on the keypad twice. The keypad displays:
6. Enter a 2-digit response type such as 01 (Entry/Exit). Press the [ ] to accept the entry.
7. Press the [ ] repeatedly until the keypad displays:
8. Enter 11 (DSM) and then press [ ] to accept the entry. The keypad displays:
9. Enter a 2-digit access point number corresponding to the access point to be tested. Press
[ ] to accept the entry.
10. Press the [ ] repeatedly until the keypad displays:
11. Enter 000 and then press the [ ] to accept the entry. The keypad displays:
12. Press 1 to quit the menu mode and then enter #99 to exit programming.
ZONE PROG?
1 = YES
0 = NO
Set to Confirm?
1 = YES
0 = NO
ENTER ZONE NO.?
000 = QUIT
100 ZONE RESPONSE
100 INPUT TYPE
100 Access Point
(01-15)
ENTER ZONE NO.?
000 = QUIT
QUIT MENU MODE?
1 = YES 0 = NO
Section 4 – Detailed Installation
0
4–7

Hide quick links: