ADEMCO VistaKey-SK Installation & Setup Manual page 54

Single-door access control starter kit
Hide thumbs Also See for VistaKey-SK:
Table of Contents

Advertisement

VistaKey Installation Guide
010 Access Point
(01-15)
010 ZT P RC B IN L
01 2 3C 0 D M 1
5–14
If you pressed 11, 12, or 13, the system advances to the "Access
Point" prompt. If you pressed 06, the system advances to the "Smart
Contact" prompt or "V-Plex Relay" prompt.
010 Smart Contact
1 = YES 0 = NO
010 V-PLEX RELAY
1 = YES 0 = NO
Enter the 2-digit (01-15) door number for the VistaKey.
3
NOTE: The response to this question must be the address that was
set in the VistaKey module for the door (access point) being
programmed.
Press [ ] to continue.
If you entered an Input Type of 11, 12, or 13 above, the alarm
system advances to the summary prompt. If you entered an Input
Type of 06 and an access point number from 1 to 15 in the previous
steps, the following "Input S/N:L" prompt appears for enrollment of
the VistaKey serial number.
010 INPUT S/N:L
Axxx-xxxx:1
The summary screen for the zone appears.
NOTE: The input type for the device (IN) portion of the display is
dependent on the choice made at the INPUT TYPE prompt above; it
is either RE (type 12 – Request to Exit), GP (type 13 – General
Purpose), or DB (type 06 – Door Status Monitor Backup).
Press [ ] to accept the zone information.
The alarm system control will return to the "ENTER ZONE NO."
prompt.
Press [0] and then press [ ] to continue.
0
NOTE: This prompt is not displayed on
some alarm systems.
Press [0] and then press [ ] to continue.
0
To enroll the VistaKey (DSMB) serial
number:
1. Remove power from the VistaKey
module.
2. Activate the DSM Zone until the keypad
beeps twice and the VistaKey serial
number is displayed.
3. Remove the fault from the DSM Zone
and re-apply power to the VistaKey.
NOTE: When you enroll the VistaKey
DSMB zone, you assign it to loop 1; loop 2
must be unused.
Press [ ] to continue.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents