010 BELL/RLY SEL
0
010 INPUT TYPE
RF Xmitter
3
(Refer to the System Communication section of your alarm system
manual for more information about report codes and report code
formats.)
Press [ ] to continue.
Each zone can be assigned to activate either one or both bell outputs
and/or the system's auxiliary relay. Enter one of the following
assignments:
0=none; 1=Bell 1; 2=Bell 2; 3=Bells 1 & 2; 4=Aux Relay; 5=Bell 1 &
Aux Relay; 6=Bell 2 & Aux Relay; 7=Bells 1 & 2 & Aux Relay.
Press [ ] to continue.
Valid choices for this prompt, when programming the VistaKey, are
Door Status Monitor (DSM), Request to Exit (RTE), General
Purpose (GP), and serial number polling loop device (DSM Backup
[DSMB]). The purpose of these input types are as follows:
DSM – This input type is used to map an access point to a zone.
When the access point is bypassed, the controlled door is propped,
or the controlled door is forced, the DSM operates according to the
zone response type. The DSM device is normally a magnetic switch
mounted on the door. The status of the switch is different while
the door (access point) is in an open condition.
RTE – This input type is used to map an uncommitted RTE zone
to an alarm panel zone. This input type is not normally used if the
RTE zone is being used for a request to exit function. The RTE
device may be something as simple as a momentary contact switch
or as complex as a motion detector.
GP – This maps the GP zone to an alarm panel zone. This input
type operates in the same manner as other VISTA alarm panel
zones and is provided so that a zone in the proximity of the
VistaKey can be wired without having to run additional wiring
from the VISTA alarm panel. This zone is normally used for
tamper in installations requiring supervision of the cabinet cover.
SERIAL POLL (DSMB) – The Serial Polling Loop input type (for
DSMB) maps the SIM in the VistaKey to an Alarm Panel zone. In
the event local power to the VistaKey is lost, the status of the DSM
can no longer be reported to the panel via the normal micro-
processor circuits of the VistaKey. In this case a Vplex SIM, which
is located on the VistaKey board and powered directly from the
polling loop, is activated and reports the state of the DSM via the
standard Vplex polling system.
Enter the input device type as follows:
06 = serial number polling loop device (VistaKey DSM Backup
Zone [VKey DSMB])
NOTE: To obtain the DSMB function, this location (INPUT
TYPE) must be defined as 06 and the next prompt (Access
Point) must contain the Access Point # (01-15).
11 = VistaKey DSM Zone (VKey DSM)
12 = VistaKey RTE Zone (VKey RTE)
13 = VistaKey GP Zone(VKey GP)
Press [ ] to continue.