Table 5-1: Action Codes - ADEMCO VistaKey-SK Installation & Setup Manual

Single-door access control starter kit
Hide thumbs Also See for VistaKey-SK:
Table of Contents

Advertisement

ACTION
ACTION
NO.
NAME
Relay Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for relay commands.
"During" can be used to control the relay for a specific time only. For example, if "during" is selected with Relay On, the system will
automatically energize the relay at the beginning of the window and automatically de-energize the relay at the end of the window.
01
Relay On
02
Relay Off
03
Rly On 2 Sec
04
Relay xx Min
05
Relay yy Sec
06
Rly Grp On
07
Rly Grp Off
08
Rly Grp 2 Sec
09
Rly Grp xx Min Relay Group #
10
Rly Grp yy Sec Relay Group #
Arm/Disarm Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for automatic arming and disarming functions.
"During" can be used to arm or disarm the control for a specific time only. For example, if "during" is selected with Arm-STAY, the system will
automatically Arm-STAY at the beginning of the window and automatically disarm at the end of the window.
20
Arm STAY
21
Arm AWAY
22
Disarm
23
Force Arm
STAY
24
Force Arm
AWAY
Bypass Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for bypass commands. If 3 (During) is selected for auto-
bypassing, the system will bypass the zone(s) specified on a particular zone list at the beginning of the window and unbypass the zone(s) at
the end of the window. If it is selected for auto unbypassing, the system will remove the bypass of the zone(s) at the beginning of the
window and will restore the bypass of the zone(s) at the end of the window.
30
Bypass Zn List Zone list #
31
Unbyps Zn List Zone list #
Open/Close Windows
Activation time 3 (During) is the only valid choice for these commands. When using Enable Open Window, Enable Close Window, and
Enable Access Window, the window is active for the partitions selected by the specifier except as follows:
• When an Event/Action occurs that would disable a window (partition not selected), the window for the partition is only disabled if it is not
currently enabled by a timed method (e.g., O/C schedule, Time-Driven Event, Access Schedule).
• When a timed window (e.g., O/C schedule, Time-Driven Event, Access Schedule) occurs that would disable a window (partition not
selected), the window for the partition is only disabled if it is not currently enabled by an Event/Action.
40
En Open Wind Partition(s)

Table 5-1: Action Codes

ACTION
ACTION
SPECIFIER
DESCRIPTION
Relay #
Relay On – Turn on relay indicated by the specifier
Relay #
Relay Off – Turn off relay indicated by the specifier
Relay #
Relay Close for 2 seconds – Close relay indicated by the specifier for 2
seconds
Relay #
Relay Close XX minutes – Close relay indicated by the specifier for XX
minutes (XX minutes set in field 1*74)
Relay #
Relay Close YY seconds – Close relay indicated by specifier for YY seconds
(YY seconds set in field 1*75)
Relay Group #
Relay Group On – Turn on relay group indicated by specifier
Relay Group #
Relay Group Off – Turn off relay group indicated by the specifier
Relay Group #
Relay Group Close for 2 seconds – Close all relays in the group indicated by
the specifier for 2 seconds
Relay Group Close XX minutes – Close relay group indicated by the specifier
for XX minutes (XX minutes set in field 1*74)
Relay Group Close YY seconds – Close relay group indicated by the
specifier for YY seconds (YY seconds set in field 1*75)
Partition(s)
Arm STAY – Arm the partition(s) indicated by the specifier in the STAY mode
Partition(s)
Arm AWAY – Arm the partition(s) indicated by the specifier in the AWAY
mode
Partition(s)
Disarm – Disarm the partition(s) indicated by the specifier
Partition(s)
Force Arm STAY – Force arm the partition(s) indicated by specifier in the
STAY mode (auto-bypass faulted zones)
Partition(s)
Force Arm AWAY – Force arm the partition(s) indicated by the specifier in
the AWAY mode (auto-bypass faulted zones)
Auto bypass zone list – Automatically bypass the zone list indicated by the
specifier
Auto unbypass zone list – Automatically unbypass the zone list indicated by
the specifier
Enable Opening Window by partition – Enable the opening window for the
partition indicated by the specifier (used to control central station reporting -
see Open/Close Reports by Exception in your alarm system manual for
additional information)
Section 5 - Programming