94 Testing ISDN BRI functions
Procedure 32
Perform a Call Join test on Conference
Step
1
2
3
4
5
6
7
8
9
10
11
Copyright © 2003-2009 Nortel Networks
.
two parties should still be connected, for two outgoing trunk calls,
in which case all parties should be disconnected.
Action
In the DSL configuration in LD 27, set PRID = 6 to select the
National ISDN-1 protocol, or PRID = 2 for ETSI protocol.
In the TSP configuration in LD 27, define conference under
FEATID:
FEATID aaa mmm <nnn>, where
aaa = A03 (3-party conference) or A06 (6-party conference)
mmm = feature activation ID (0 - 127)
nnn = feature indication ID (0 - 127) (If nnn is not entered, it is
assumed to be the same as mmm)
On the ISDN BRI terminal, if the signaling type/protocol is
configurable, then select National ISDN-1or ETSI protocol.
On the ISDN BRI terminal, configure Conference. This
procedure largely depends on the implementation of feature key
management on individual terminals. In general:
a The terminal provides Conference as a selectable feature to
be programmed on a hard/soft key. For example, on a soft
key on an M5317TDX, select FA to be FCC; on a hard key on
an M5209TDcp, select CONF.
b The Conference key number selected on the terminal must
correspond to the feature activation ID entered for the TSP
in LD 27.
Configure at least two DN appearances on the ISDN BRI
terminals. On some ISDN BRI terminals, the second DN
appearance is used to allow the user to initiate the second call.
Place an outgoing call from the ISDN BRI terminal.
After the first call is established, place an incoming call to the
ISDN BRI terminal.
Hold the first call and answer the second call.
Press the Conference key; the second call is put on hold.
Retrieve the first call and press the Conference key again. All
three parties should be in a conference.
Press the RELEASE key to drop from the call. The ISDN BRI
user should be disconnected from the conference; the remaining
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 03.01
11 May 2009
--End--