Table 2
ISDN BRI card location (cont'd.)
2
The following rules apply when selecting the card slots:
MISPs
BRSCs
Copyright © 2003-2009 Nortel Networks
.
Modules
NT8D35
Network Module
NT8D37
IPE Module
Locate the card slots in the modules that house ISDN BRI cards.
Group all SILCs, UILCs, BRSCs, superloops and the MISP that
supports them in the same network group to avoid using junctors
for dedicated connections.
MISPs are inserted into the Core/Network Module for Large Systems
(Multi Group). Refer to the LD 22 printout to identify modules with
unused network card slots and to
(page 16)
for the card slots in these modules that can house MISPs.
An MISP cannot share network loop addresses with a Superloop
Network Card in the Large Systems. The MISP requires two network
loop addresses and one network card slot.
An MISP supports a maximum of 8 BRSCs and two line cards.
An MISP supports a set of 4 SILCs or UILCs when not supporting a
BRSC.
An MISP can support both BRSCs and SILCs or UILCs at the same
time. If it serves one BRSC, an MISP can also support three line cards.
If it supports two or more BRSCs, an MISP can also support two line
cards.
Install one BRSC for each IPE module.
With a BRSC configured, an IPE module can support a maximum of 15
line cards. These can be up to eight UILCs combined with any other
seven peripheral cards (including SILCs), or up to 15 SILCs.
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 03.01
11 May 2009
Installing ISDN BRI hardware for line applications 17
Supported
Systems
81C CPPII
All systems
--End--
Table 2 "ISDN BRI card location"
SILCs,
UILCs,
BRSCs
MISPs
Network
slots 5-12
IPE slots
0-15