Nortel CS 1000 Series Installation And Commissioning Manual page 70

Isdn basic rate interface
Hide thumbs Also See for CS 1000 Series:
Table of Contents

Advertisement

70 Configuring ISDN BRI hardware
2
3
4
5
Table 16 "SILC and UILC port assignments connectors at cross-connect
terminal" (page 70)
at the cross-connect terminal.
Table 16
SILC and UILC port assignments connectors at cross-connect terminal
SILC port
signals
0 TX-
0 TX+
0 RX-
0 RX+
1 TX-
1 TX+
1 RX-
1 RX+
2 TX-
2 X+
2 RX-
2 RX+
3 TX-
3 TX+
Note: The cable pair designated TX- TX+ is the transmit pair and the pair
designated RX+ RX- is the receive pair of the S/T interface. The cable pair
designated T R is the Tip and Ring of the 2B1Q full-duplex U interface.
Copyright © 2003-2009 Nortel Networks
.
Identify the transmit and receive connections for the SILC and
the TIP and RING connections for the UILC from the label of the
distribution strip.
Refer to
Table 19 "M5317TDX terminal error codes" (page 80)
identify ports and their connections for a SILC or UILC.
Identify building wires connected at the cross-connect terminal.
Cross-connect the pins from the SILC or UILC to the building
wiring.
Repeat this procedure for each DSL.
identifies SILC and UILC port assignments connectors
UILC port
signals
0 T
0 R
1 T
1 R
2 T
2 R
3 T
3 R
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 03.01
11 May 2009
--End--
Connector
pin number
Wire
and wire
color
color code
codes
26
W-BL
1
BL-W
27
W-O
2
O-W
28
W-G
3
G-W
29
W-BR
4
BR-W
30
W-S
5
S-W
31
R-BL
6
BL-R
32
R-O
7
O-R
to
Card ports
Port 0
Port 1
Port 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1000eCs 1000m

Table of Contents