76 Configuring ISDN BRI hardware
Procedure 23
Connecting the ISDN BRI terminals to the DSL
Step
1
2
3
4
5
Copyright © 2003-2009 Nortel Networks
.
Action
Plug one end of the modular cable into the ISDN BRI interface
connector on the terminal. Plug the other end of the modular
cable into the telephone outlet.
If the SILC S/T interface has an optional auxiliary power source,
plug the power source into the wall outlet and then the 10-m
(33-ft) modular cable into the power source's RJ-45 type jack.
The power source must not feed the power back into the
DSL through the RJ-45 wall outlet, only to the local ISDN BRI
terminal. The power adapter is normally supplied with the
terminal.
Figure 28 "Connecting the ISDN BRI terminal to the S/T
interface" (page 77)
to an S/T interface.
terminator to the U interface" (page 78)
terminal connection to a U interface.
Enter the Static TEI at the terminal.
Note: Do not perform this step to assign Dynamic TEIs since
they are automatically assigned.
Enter the Service Profile ID number at the terminal.
For detailed information about this procedure, refer to the
terminal user guide.
Repeat
step 1
to
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 03.01
11 May 2009
illustrates an ISDN BRI terminal connection
Figure 29 "Connecting the ISDN network
step 4
for each ISDN BRI terminal.