Chapter 6: Troubleshooting

PWR 1 and PWR 2 LEDs

80
Problem: A DC power supply is connected to the switch, but the
corresponding PWR 1 or PWR 2 LED on the front panel is off.
Solutions: The unit is not receiving power from the power supply or the
power is outside the operating range of the switch. Try the following:
Verify that the DC power source is powered on and operating
normally.
Review the DC power source's documentation to verify that it is
compatible with the switch. The power supply requirements for the
switch are given in "Power Supplies" on page 39.
Verify that the power/alarm connector is fully inserted into the slot
in the top panel of the switch.
Verify that the DC wires are securely connected to the PWR 1 -
PWR 2 connector terminals on the switch and to the DC power
supply.
Verify that the DC positive and negative wires from the power
supplies are connected to the correct connectors on the DC PWR
1 - PWR 2 connector terminals on the switch.
Try using a different DC power source.
Try replacing the DC power wires.
Try connecting the DC power source to a different device to ensure
that it is working properly.
Test the output voltage from the power source to verify that it is
within the operating range of the switch.