Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc.
How to Start an AT-GS950/16 WEB Management Session This document contains the procedures to start you Web management session on the AT-GS950/16 switch. The following topics are discussed: “Establishing a Remote Connection to the Web Browser Interface” on page 4 “Web Browser Tools”...
How to Start an AT-GS950/16 WEB Management Session Establishing a Remote Connection to the Web Browser Interface The AT-GS950/16 switch is shipped with a pre-assigned IP address of 192.168.1.1. After your initial login, you may want to assign a new IP address to your switch.
Page 5
How to Start an AT-GS950/16 WEB Management Session The AT-S108 Management Software displays the login dialog box, shown in Figure 2. Figure 2. Management Login Dialog Box 3. Enter the AT-S108 management login user name and password. The default user name is “manager” and the default password is “friend.”...
Page 6
How to Start an AT-GS950/16 WEB Management Session Figure 3. AT-S108 Home Page The main menu appears on the left side and is common for all of the management pages discussed in this manual. It consists of the following folders and web pages: Switch Info.
Page 7
The AT-S108 Management software displays the front of the switch. Ports that have a link to an end node are green. Ports without a link are grey. The AT-GS950/16 switch front panel page is shown in Figure 4. Figure 4. AT-GS950/16 Front Panel Page A web browser management session remains active even if you link to other sites.
How to Start an AT-GS950/16 WEB Management Session Web Browser Tools You can use the web browser tools to move around the management pages. Selecting Back on your browser’s toolbar returns you to the previous display. You can also use the browser’s bookmark feature to...
How to Start an AT-GS950/16 WEB Management Session Configuration of IP Address, Subnet Mask and Gateway Address This procedure explains how to change the IP address, subnet mask, and gateway address of the switch. Before performing the procedure, note the...
Page 10
How to Start an AT-GS950/16 WEB Management Session System Default Gateway - Displays the default gateway of the switch. To change the default gateway, enter a new gateway. When DHCP is enabled, you cannot change this parameter. DHCP Mode - For information about setting this parameter, refer to “DHCP Client Configuration”...
How to Start an AT-GS950/16 WEB Management Session IP Access List Configuration When the IP Access List feature is enabled, remote access to the AT-S108 management software is restricted to the IP addresses entered into the IP Access List. The procedures in this section describe how to enable or disable the IP Access List feature and how to add or remove IP addresses from the list.
Page 12
How to Start an AT-GS950/16 WEB Management Session Note You can add up to 10 IP address to the IP Access List table.
Page 13
How to Start an AT-GS950/16 WEB Management Session 5. From the IP Restriction Status field, select one of the following choices from the pull-down menu: Enable - This selection restricts the access to the AT-S108 management software to the IP addresses in the table listed under Accessible IP.
How to Start an AT-GS950/16 WEB Management Session System Time The procedures in this section describe how to configure the system time by manually entering the time or through SNTP and how to configure the daylight savings time feature. See the following sections: “Manually Setting System Time”...
Page 15
How to Start an AT-GS950/16 WEB Management Session 3. Use the pull down menu to set the Clock Mode parameter to Local time. 4. In the Local Time Settings section, set the Date Setting (YYYY:MM:DD) to the current date in the YYYY:MM:DD format.
Page 16
How to Start an AT-GS950/16 WEB Management Session Setting Daylight If you want to configure the switch for daylight savings time, perform the following procedure: Savings Parameters 1. From the main menu on the left side of the page, click the System folder.
How to Start an AT-GS950/16 WEB Management Session DHCP and ATI Web Discovery Tool The AT-GS950/16 Gigabit Ethernet Smart switch is managed through a web browser interface only. The factory default IP address is 192.168.1.1. The switch does not have a local console connector, which means that you cannot learn what the switch’s management IP address is on a web...
DHCP Client Configuration This procedure explains how to activate and deactivate the DHCP client on the AT-GS950/16 switch. When the client is activated, the switch obtains its IP configuration including an IP address and subnet mask from a DHCP server on your network. Before performing the procedure, note the following: By default, the DHCP client is disabled on the switch.
Page 19
How to Start an AT-GS950/16 WEB Management Session Note The ATI Web Discovery Tool is available for download on the AT-GS950/16 product page at alliedtelesis.com. 6. Follow the procedure to log on with the new IP address provided by the DHCP Server as described in “Establishing a Remote Connection to...
How to Start an AT-GS950/16 WEB Management Session DHCP Auto Configuration If you need to automatically update the switch’s configuration files via a remote server, the DHCP Auto Configuration feature is available for this purpose via the DHCP server. Note You must enable the DHCP client so that this feature can operate with the DHCP server.
This section explains how to assign a name, location, and contact information for the AT-GS950/16 switch. This information helps in identifying each specific AT-GS950/16 switch among other switches in the same local area network. Entering this information is optional. Note Allied Telesis recommends that you assign a name to the switch.
Page 22
How to Start an AT-GS950/16 WEB Management Session System Name - Specifies a name for the switch, for example, Sales. The name is optional and may contain up to 15 characters. System Location - Specifies the location of the switch. The location is optional and may contain up to 30 characters.
How to Start an AT-GS950/16 WEB Management Session User Name and Password Configuration Password protection is always enabled for access to the AT-S108 Management software. This section explains how to create new users names and passwords and how to modify or delete existing users for the web interface.
Page 24
How to Start an AT-GS950/16 WEB Management Session 4. To add a password that corresponds to the user name entered in step 3, enter a password of up to 12 alphanumeric characters in the box next to the Password field. The Password field is case sensitive.
Page 25
How to Start an AT-GS950/16 WEB Management Session Delete User Name To delete a user name that you have previously added, perform the following procedure. and Password 1. From the main menu on the left side of the page, click the System folder.
The Web Server Status is displayed as Enabled for your information only. The Web Server cannot be disabled. SNMP Interface To enable or disable the AT-GS950/16 SNMP interface, perform the following procedure: 1. From the main menu on the left side of the page, click the System folder.
Page 27
How to Start an AT-GS950/16 WEB Management Session 5. From the main menu on the left side of the page, select Save Configuration to Flash to permanently save your changes. User Interface To set the Web Idle Timeout, perform the following procedure: Timeout 1.
System Information Display The Switch Information page is initially displayed when you first log into the AT-GS950/16 switch. It provides general information about the switch. To view this information, perform the following procedure: 1. From the main menu on the left side of the page, select Switch Info.
Page 29
How to Start an AT-GS950/16 WEB Management Session Administration Information Section: Switch Name - This parameter displays the name assigned to the switch. To assign the switch a name, refer to “System Management Information” on page 21. Switch Location - This parameter displays the location of the switch.
How to Start an AT-GS950/16 WEB Management Session Switch Reboot You can reboot the AT-GS950/16 switch by either pressing the front panel eco-friendly switch between 5 to 9 seconds or by using the Normal reboot function provided in the AT-S108 management software.
Page 31
Allied Telesis has no knowledge of it. You are responsible for keeping the password in a safe place. If it is lost, Allied Telesis does not have a way to help you recover it. See “Disabling Factory Default Reset Feature” on page 34 for information about how to disable the factory default reset feature.
How to Start an AT-GS950/16 WEB Management Session Figure 14. Factory Default Reset/Reboot Page 3. Go to the lower part of the page to the Reboot section. 4. In the Reboot Type field, select Normal from the pull-down menu. When the switch is rebooted with this selection, all configuration parameters that are saved in flash memory are loaded into the switch’s...
Page 33
How to Start an AT-GS950/16 WEB Management Session Caution This procedure causes the switch to reboot. The switch does not forward network traffic during the reboot process. Some network traffic may be lost. To return the AT-S108 Management software to the default settings,...
How to Start an AT-GS950/16 WEB Management Session 5. Click Apply. The switch begins the reboot process. You must wait approximately two minutes for the switch to complete the reboot process before you can re-establish your management session and network traffic begins flowing normally again.
Page 35
Allied Telesis has no knowledge of it. You are responsible for keeping the password in a safe place. If it is lost, Allied Telesis does not have a way to help you recover it. 6. Re-enter the same password in the Confirm Password field.
Page 36
How to Start an AT-GS950/16 WEB Management Session Enabling Factory If the Factory Default Reset feature is disabled and you choose to Enable it, perform the following procedure: Default Reset 1. From the main menu on the left side of the page, select the Tools folder.
How to Start an AT-GS950/16 WEB Management Session Pinging a Remote System This procedure instructs the AT-GS950/16 switch to ping a node on your network. This procedure is useful in determining whether an active link exists between the switch and another network device.
Page 38
How to Start an AT-GS950/16 WEB Management Session 5. To view the ping results, click Show Ping Results. A sample Ping Test Results Page is displayed. See Figure 19. Figure 19. Ping Test Results Page The following information is displayed: Destination IP Address - Indicates the IP address of the unit that receives the ping.
HTTPS mode with SSL protocol are protected against snooping because the packets exchanged between the switch and your management workstations are encrypted. When operating in this mode, only the AT-GS950/16 switch and the web browser are able to decipher the packets sent and received between them. Configuring SSL...
Page 40
How to Start an AT-GS950/16 WEB Management Session 4. Click Apply. The SSL setting that you have selected is now active. 5. From the main menu on the left side of the page, select Save Configuration to Flash to permanently save your changes.
How to Start an AT-GS950/16 WEB Management Session System Log Configuration The System log is designed to monitor the operation the AT-GS950/16 switch by recording the event messages it generates during normal operation. These events may provide vital information about system activity that can help in the identification and solutions of system problems.
Page 42
How to Start an AT-GS950/16 WEB Management Session 3. From the Syslog Status field, select one of the following choices from the pull-down menu: Enable - The System log is active. Disable - The System log is inactive. 4. From the Time Stamp field, select one of the following choices from...
How to Start an AT-GS950/16 WEB Management Session Returning the AT-S108 Management Software to the Factory Default Values This procedure returns all AT-S108 Management software parameters to their default values and deletes all tagged and port-based VLANs on the switch.
How to Start an AT-GS950/16 WEB Management Session Quitting a Web Browser Management Session To exit a web browser management session, close the web browser.
Need help?
Do you have a question about the AT-GS950/16 and is the answer not in the manual?
Questions and answers