Analyser Problem Solving - Kane 456 Manual

Flue gas analyser with direct co2 measurement
Table of Contents

Advertisement

8. ANALYSER PROBLEM SOLVING

If any problems are not solved with these solutions, contact us or an authorized repair
center.
Fault symptom
• Oxygen too high
• CO
too low
2
• Batteries not holding charge
• Analyser not running on mains
adapter.
• Analyser does not respond to flue
gas
• Net temperature or Efficiency
calculation incorrect.
• Flue temperature readings erratic
• T flue or T nett displays (-N/F-)
EFF or X-Air displays (- O2++-)
• Analyser just continually beeps
Causes / Solutions
• Air leaking into probe, tubing, water trap,
connectors or internal to analyser.
• Batteries exhausted.
• AC charger not giving correct output.
• No fuse
• Particle filter blocked.
• Probe or tubing blocked.
• Pump not working or damaged with
contaminants.
• Ambient temperature set wrong during
Automatic Calibration.
• Temperature plug reversed in socket.
• Faulty connection or break in cable or
plug.
• Probe not connected.
• Faulty connection or break in cable or
plug.
• CO
reading is below 2%.
2
• 02 > 18%
• Turn dial back to MENU and press ENTER
• Turn dial back to Tightness and press
ENTER