KANE456 OVERVIEW

The KANE456 Combustion Analyser measures carbon dioxide (CO
monoxide (CO), differential temperature and differential pressure. The direct
measurement of CO
Below 1% CO
the readings of CO
2
CO
is set to zero in fresh air automatically after the initial countdown. The countdown
2
varies between 90 and 30 seconds dependent on ambient temperature.
If "RESET GAS ZERO" is indicated ensure that the unit is in fresh air before pressing
the button with an "Enter" symbol.
It calculates oxygen (O
Condensing Gross).
The KANE456 Combustion Analyser can also measure CO levels in ambient air -
useful when a CO Alarm is triggered. It can also perform a Room CO Test for up to 30
minutes duration.
A structured Commissioning Test has been included for the installation of boilers.
The analyser has a protective rubber cover with a magnet for "hands–free" operation
and is supplied with a flue probe with integral temperature sensor.
A low flow detection system warns of low flow and switches the pump off. This also
helps to prevent water ingress from overfilled water traps.
Its LCD display is protected with a toughened screen.
The large display shows 6 readings at a time and all data can be printed via an
optional infrared printer. The printed data can be 'live' data or 'stored' data.
The memory can store up to:
60 combustion tests
20 AUX tests
20 let-by/tightness tests
20 temperature & pressure tests
20 room CO tests
20 commissioning Tests
Two lines of 20 characters can be added to the header of printouts. Printouts can be
made on the optional Kane IRP printers with 'fast print' capability using the IRP2
printer. Alternatively the analyser can be equipped with optional wireless
communications to either Android or Apple devices.
The analyser is controlled using 4 function buttons and a rotary dial.
The four buttons (from left to right) switch on and off the analyser, switch on and off
the torch light, switch on and off the pump and send data to a printer or to the memory.
The buttons with UP, DOWN and ENTER arrows also change settings such as date,
time, fuel, etc. when in MENU mode.
is achieved using a Kane designed infra-red sensing system.
2
are displayed to two decimal places
2
), CO/CO
ratio, losses, combustion efficiency (Net or
2
2
)
carbon
2
,