Pressure Units - Kane 456 Manual

Flue gas analyser with direct co2 measurement
Table of Contents

Advertisement

PRS :
Pressure reading, either single point or differential.
BAT :
Displays the Battery power available.
Readings may be affected if used with low power batteries.
DATE :
Date shown as day, month and year, DD/MM/YY. Date is recorded
when each combustion test is printed or stored.
TIME :
The time shown is expressed in "Military" time HH:MM:SS. Time is
recorded when each test is printed or stored.
Note! When changing the batteries on the instrument the memory
will store the date and time for up to one minute, if outside this
time it may be necessary to re-enter the details.
Date and time may also need to be reset if re-chargeable batteries
are allowed to totally discharge.
FULL :
The maximum number of tests have been stored in the memory. To
delete the stored memory, Select Reports then select the tests to be
deleted (see Page 23).

Pressure units:

m:
millibar
s:
psi
h:
hPa
P:
Pa
g:
mmHg
i:
inH2O