HAWK 5000 OPERATOR MANUAL
HAWK5000
Operators
Manual
Kane International Limited
Kane House, Swallowfield
Welwyn Garden City
Hertfordshire
AL7 1JG
Tel: +44 (0)1707 375550
Fax: +44 (0)1707 393277
Stock No 13756 / 8
March 2002
© Kane International Limited
KANE INTERNATIONAL LIMITED
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hawk5000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kane Hawk5000

  • Page 1 HAWK 5000 OPERATOR MANUAL HAWK5000 Operators Manual Kane International Limited Kane House, Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Tel: +44 (0)1707 375550 Fax: +44 (0)1707 393277 Stock No 13756 / 8 March 2002 © Kane International Limited KANE INTERNATIONAL LIMITED...
  • Page 2: Table Of Contents

    ON-SITE ......................8 CONFIRMING CORRECT OPERATION ...............9 THE PHASER ......................10 USING PULSE INPUT DEVICES .................11 DOWNLOADING DATA ..................12 TROUBLESHOOTING...................13 TECHNICAL INFORMATION ................14 SPECIFICATION ....................15 WORKING CONDITIONS..................16 MAINTENANCE AND CLEANING CONDITIONS..........16 CONNECTIONS......................17 CE MARKING......................18 LOW VOLTAGE DIRECTIVE................18 GLOSSARY ......................19 KANE INTERNATIONAL LIMITED...
  • Page 3: General Information

    HAWK 5000 OPERATOR MANUAL GENERAL INFORMATION This is the section, which gives you an introduction to the HAWK5000 system and its hardware. It will make the subsequent operation easier to understand if you read through this first. Software operations are separately described in the Hawk Commander and Hawk Reporter Professional text files.
  • Page 4 The HAWK measures mains voltage and frequency from its mains supply. The other two phases of a three-phase system are assumed to have the same amplitude, waveform and frequency, but to be 120 degrees apart. The HAWK5000 does not require any connections to live bare conductors. KANE INTERNATIONAL LIMITED...
  • Page 5: Requirements

    HAWK 5000 OPERATOR MANUAL Range of measurements... HAWK5000 is capable of measuring any or all of the following: Current x 3 phases Power x 3 phases x 3 phases Total Reactive power x 3 phases Lagging reactive power x 3 phases...
  • Page 6: Electromagnetic Compatibility

    At the time of updating this manual Kane International Ltd is not aware of any field based situation where such interference has ever occurred and this advice is only given to satisfy the requirements of the Directive.
  • Page 7: Getting Started With The Hawk5000

    HAWK 5000 OPERATOR MANUAL GETTING STARTED WITH THE HAWK5000 OVERVIEW The operations required to perform a survey are: a) Connect the HAWK to a PC and run the Commander or Hawk Reporter Professional program. b) Enter the SET-UP section of the program.
  • Page 8: On-Site

    Assuming that the HAWK has previously been set up, and you are now at the site to be surveyed: If you can arrange to have a portable computer with you, the HAWK5000 software and a suitable serial lead, this will allow you to verify correct operation, and also to change the set-up, or start a new survey if necessary.
  • Page 9: Confirming Correct Operation

    CT, or connecting the one offending CT the other way around on the cable. 4. When none of the three green CT lights are flashing, all connections are correct. 5. The values being measured may be viewed by connecting a portable computer to the HAWK. KANE INTERNATIONAL LIMITED...
  • Page 10: The Phaser

    (PP3 type) battery. Since it is used very infrequently for short periods the battery should last for many years. If the battery does require replacing access can be obtained by removing the two screws that hold the case together. KANE INTERNATIONAL LIMITED...
  • Page 11: Using Pulse Input Devices

    +12V DC power out pin. Note that this power output is unregulated, and so can rise well above 12 Volts. Up to a total of 100 milliamps may be drawn from the two pulse connector power out pins. KANE INTERNATIONAL LIMITED...
  • Page 12: Downloading Data

    Back at the office, connect the mains cable to the HAWK, and switch on. Connect the serial cable between the HAWK and the PC. Run the HAWK5000 control program on the PC, and download the stored data. KANE INTERNATIONAL LIMITED...
  • Page 13: Troubleshooting

    Click SCAN NOW to try to re-establish communication Starting a survey : Logging light doesn't flash A new survey has not been started: Use HAWK5000 control program to start a new survey. Start time not yet reached: Use HAWK5000 control program to change start time.
  • Page 14 Some or all data is zero: Are either of the input scale factors zero? Were any or all of the CT clamps connected incorrectly? Try using survey OVERVIEW to check that all the data really is zero. KANE INTERNATIONAL LIMITED...
  • Page 15: Technical Information

    1000 kW Resolution 0. 1% Accuracy 1, 3 Notes: Excludes CT accuracy With 1000: 1 CTs Assumes all three voltages are equal and equispaced Exceeds the range over which the HAWK will function Reduced accuracy below this range KANE INTERNATIONAL LIMITED...
  • Page 16: Working Conditions

    Clean the handle and casing with a cloth moistened with a light detergent, use a cloth slightly moistened with clean water to remove residues. Dry with clean soft cloth, never expose the clamp to running water. After cleaning leave overnight in a warm room to ensure that all moisture evaporates. KANE INTERNATIONAL LIMITED...
  • Page 17: Connections

    1 Low frequency input 2 Ground 3 High frequency input 4 +12V DC power out 5 Not connected The current transformer input connections are: 1 AC current in 2 aux. 3 AC current return 4 +V aux. 5 -V aux. KANE INTERNATIONAL LIMITED...
  • Page 18: Ce Marking

    Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50%RH at 40°C Mains supply 180-260V AC Inputs and connections other than the mains voltage supply should not exceed 30V rms and 42.4 V peak or 60 V DC. KANE INTERNATIONAL LIMITED...
  • Page 19: Glossary

    The value stored is the average of all the measurements taken during the last logging period. Measurement period: The time between making a measurement of inputs (e.g. every 3 seconds). Sample rate: The rate at which individual instantaneous samples of the input are taken (e.g. 10,000 per second) during a measurement. KANE INTERNATIONAL LIMITED...