Possible Fault; Troubleshooting A Cable-Tie Bandoleer; Malfunction - HellermannTyton Autotool 2000 CPK Operating Instructions Manual

Hide thumbs Also See for Autotool 2000 CPK:
Table of Contents

Advertisement

DISPLAY MESSAGE
Time loss
1. Check battery in power pack
2. Press Reset button

10 .4 Possible fault

FAULT PATTERN
Loops form
Binding not possible.
Cable tie shoots straight
out.
Cable tie is not cut off
flush.

10 .4 .1 Troubleshooting a cable-tie bandoleer

malfunction

Be sure to check the information on the display, à "Display
messages" on page 30.
f Switch the power pack OFF.
1
f Push the actuator for bandoleer cutter
f Press the catch
.
3
f Open the gate
.
1
Operating Instructions • AT2000 CPK • 07-2019 • v03 • 106-29004
POSSIBLE CAUSE
• The back-up battery for the
clock in the power pack has
discharged.
POSSIBLE CAUSE
• Bundle diameter is
unsuitable.
• Tie advancer is not in the
correct position.
• Spring in upper jaw is faulty.
• Lower jaw is blocked.
• Upper jaw is blocked.
• Cutter in front cap is not in
correct position.
2
3
to the left.
2
SOLUTION
f Change the back-up battery, à "Changing back-up
battery" on page 34.
f Press the Reset button.
SOLUTION
f Use a suitable bundle diameter, à "Positioning and
binding items for bundling" on page 12.
f Check the position of the tie advancer, à "Checking
tie advancer" on page 36.
f Check upper jaw flap in upper jaw with spring,
à "Replacing upper jaw" on page 35.
f Check lower jaw, à "Checking front cap and position
of cutter" on page 36.
f Remove blockage.
f Check upper jaw, à "Checking upper jaw" on
page 35.
f Remove blockage.
f Check position of cutter in front cap and remove
cable-tie residues, à "Checking front cap and position
of cutter" on page 36.
f Press the actuator for service flap left
f Open the left service flap.
f Open the right service flap.
Troubleshooting
4
.
4
33

Advertisement

Table of Contents
loading