HellermannTyton Autotool 2000 CPK Operating Instructions Manual page 32

Hide thumbs Also See for Autotool 2000 CPK:
Table of Contents

Advertisement

DISPLAY MESSAGE
Error, drum
1. Operate bandoleer cutter
2. Open gate
Error, drum
1. Remove cable-tie residues
2. Press Reset button
Overload
1. Operate bandoleer cutter
2. Open gate
Overload
1. Remove cable-tie residues
2. Press Reset button
Error, tensioning motor
1. Operate bandoleer cutter
2. Open gate
Error, binding force
1. Check binding
2. Confirm with trigger
Operating Instructions • AT2000 CPK • 07-2019 • v03 • 106-29004
POSSIBLE CAUSE
• The cable tie bandoleer is
pulled in at an angle.
• Roller lever drum is jammed
or is defective.
• The drum is blocked.
• The bandoleer cutter does
not cut off the cable ties.
• The cable tie bandoleer is
pulled in at an angle.
• Drive is jammed or is
defective.
• The specified binding force
is not achieved.
The message appears only if
error notification is activated,
à "Check of binding" on
page 16.
SOLUTION
f Push actuator for bandoleer cutter to the left.
f Open the gate.
f Open the two transparent service flaps at the gate,
à "Troubleshooting a cable-tie bandoleer
malfunction" on page 33.
; Error, drum appears as the next message on the
display.
f If applicable, carefully remove the cable-tie residues.
f Open the roller lever drum and turn the drum to the
correct position.
f Press the Reset button.
; Error, gate appears as the next message on the
display.
f Close the gate.
f Load a new cable tie bandoleer, à "Loading cable
ties" on page 11.
f Push actuator for bandoleer cutter to the left.
f Open the gate.
f Open the two service flaps at the gate,
à "Troubleshooting a cable-tie bandoleer
malfunction" on page 33.
; Error, overload appears as the next message on
the display.
f If applicable, carefully remove the cable-tie residues.
f Press the Reset button.
; Error, gate appears as the next message on the
display.
f Close the gate.
f Push actuator for bandoleer cutter to the left.
f Open the gate.
f If applicable, carefully remove the cable-tie residues.
f Press the Reset button.
; Error, gate appears as the next message on the
display.
f Close the gate.
f Check the binding.
f If applicable, reset the binding force.
f If applicable, carefully remove the cable-tie residues.
f Press the trigger as confirmation.
Troubleshooting
32

Advertisement

Table of Contents
loading