Interruption Front Sensor; Date / Time; Check Of Binding; Contact Menu - HellermannTyton Autotool 2000 CPK Operating Instructions Manual

Hide thumbs Also See for Autotool 2000 CPK:
Table of Contents

Advertisement

Settings

Interruption front sensor

Date / time

Check of binding

Back
8 .3 .1 Interruption front sensor
The
Interruption front sensor
decide how long the level sensor can remain busy
without the
Error, front cap
display.
This function is intended for use with the device integrated
into an automatic system.
Settings
Interruption front sensor
Level 1
0.0 sec.
Level 2
0.3 sec.
Level 3
0.5 sec.
Level 4
0.7 sec.
Level 5
0.9 sec.
Back
f Use the Select button
2
f Press the Enter button
1
; The setting changes to the level you selected.
8 .3 .2 Date / time
You can set the
Date / time
Date and time can also be synchronised with the HTDM,
à "Synchronising time and date" on page 19.
Settings
Date
2 0 . 0 3 . 1 9
Clock time
1 0 : 2 3
f Use the Select button
2
f Press the Enter button
1
; The setting changes to the option you selected.
Operating Instructions • AT2000 CPK • 07-2019 • v03 • 106-29004
setting enables you to
message appearing on the
to select the level.
.
for process documentation.
to change the date and time.
to confirm each digit.
8 .3 .3 Check of binding
The
Check of binding
whether or not the Error, binding force
message appears on the display,
.
page 30
The binding check can also be set with the HTDM,
à "Setting the binding check" on page 19.
Settings
Check of binding
OFF
Error notification
Acknowledgement
Back
f Use the Select button
f Press the Enter button
1
; The setting changes to the option you selected.
Setting
2
OFF
Error notification
Acknowledgement
8 .4

Contact menu

The
Contact
menu shows you the current website of
the manufacturer.
Contact
1
www.HellermannTyton.com
2
Settings in the main menu
setting enables you to decide
à "Display messages" on
to select the desired setting.
2
.
1
Meaning
The Error, binding force message does
not appear on the display.
The Error, binding force message
appears when applicable but does not require
confirmation.
The Error, binding force message
appears when applicable and requires
confirmation. The next binding is not possible
until the trigger has been pulled to confirm the
message.
1
2
1
2
16