9 .8 .2 Save parameter sets

The parameter sets are saved with the file ending
"cpkpreset".
f Click on
Save in file
.
4
f Define the storage location for the files.
f In the window opened by the operating system, click on
the
Save
button.
9 .8 .4 Edit parameter sets
f Select the parameter set in the overview and click on
Edit
.
6
1
2
3
f Allocate a three-digit designation, e.g. "016" to the
parameter set in the field
The same designation cannot be allocated twice.
f Select the desired
Force level
f Select the type of binding mode in the drop-down menu
Mode
. The following settings are available:
2
• Force level
Operating Instructions • AT2000 CPK • 07-2019 • v03 • 106-29004
4
Designation
.
1
and Quality.

9 .8 .3 Load parameter sets

f Click on
Load from
file.
f Select the file with the file ending "cpkpreset".
f In the window opened by the operating system, click on
the
Open
button.
; The parameter sets are displayed in the overview
5
• Loop
f Select the type of cutting mode in the drop-down menu
Cutting mode
. The following settings are available:
3
• Cut flush
• Cut with projecting cable-tie end
• No cutting
f For delicate bundles, activate the option
cutting.