Export Process Data From The Power Pack Cpk; Troubleshooting; Important Notes - HellermannTyton Autotool 2000 CPK Operating Instructions Manual

Hide thumbs Also See for Autotool 2000 CPK:
Table of Contents

Advertisement

f Activate the option
Long hold time
; The hold time before cutting is increased. This gives the
binding more time to release tension.
If only the
Tension-free cutting
time is 100 ms, whereas the additional option
time
increases the hold time to 200 ms.
f In mode
Loop, use the
2
diameter of the bundle.
; The set diameter is shown on the display of the
AT2000 CPK.
f In cutting mode
Cut with projecting cable-tie
3
use the projecting cable-tie end slider to set the length of
the projecting cable ties.
; The set projecting cable-tie end is shown on the display
of the AT2000 CPK.
f For cut-free binding, select the cutting mode
No cutting.
f Click on
Accept
to save the settings.
6
; The overview of the parameter sets is displayed,
à "Parameter set menu" on page 27.
f Synchronisation the settings with the AT2000 CPK,
à "Synchronise parameter sets" on page 27.
9 .9
Export process data from the power pack CPK
NOTE
The power pack CPK must be restarted before the
transmission, as otherwise the CSV file will be written
incorrectly and it will not be possible to convert it.
Bindings cannot be triggered while a data transfer is in
progress.
2
f Switch the power pack CPK off and on again.
f Disconnect the power pack CPK from the PC.
f Plug a USB memory stick
The USB memory stack must be FAT32-formatted.
; The Data LED
lights up green as soon as the device
1
recognises the USB memory stick.
; The data are exported to the USB memory stick.
; The display shows the message that the AT2000 CPK
should not be switched off.
Operating Instructions • AT2000 CPK • 07-2019 • v03 • 106-29004
as well.
option is activated, the hold
Long hold
Diameter
slider to set the
4
end,
3
P o
w e
r p
a c
k C
P K
D a
ta
S ig
n a
l
P o
w e
r
1
into the power pack CPK.
2
USB active
Do not switch off
; During the saving process, the Data LED
red/blue.
; As soon as the data transfer is complete, the Data LED
lights up green.
1
f Unplug the USB memory stick
; The Data LED
goes out and the AT2000 CPK is ready
1
for use.
f Switch the power pack CPK off and on again.
f Connect the power pack CPK to the PC.
10

Troubleshooting

10 .1 Important notes

CAUTION
Crush hazard when jaws close .
f Do not insert fingers between upper and lower jaws and
do not keep your finger on the trigger.
f Always keep the power pack switched OFF when
clearing a blockage.
CAUTION
Crush hazard due to moving/rotating parts when
service flaps are open .
f Do not insert fingers underneath the drum and do not
keep your finger on the trigger.
f Always keep the power pack switched OFF when
clearing a blockage.
Troubleshooting
will light up
1
.
2
29

Advertisement