Set Zone - HIKVISION AX DS-PW32-H Series User Manual

Control panel
Hide thumbs Also See for AX DS-PW32-H Series:
Table of Contents

Advertisement

2. Select a zone and enter the Settings page.
3. Enable Zone Bypass and the zone will be in the bypass status.
The detector in the zone does not detect anything and you will not receive any
alarm from the zone.

2.5.8 Set Zone

After the detector is added, you can set the zone, including the zone name, the zone
type, zone bypass, linked camera, stay/away status, the siren, and the silent zone.
You can also view the detector serial No. (only device in 433 HMz) and the detector
type of the zone.
Steps
1. Tap a zone in the Partition page to enter the zone settings page.
2. Set the following parameters as you desired.
Zone Type
Select a zone type from the zone type list.
Zone Bypass
Enable the function and the zone will be bypassed. No alarm will be received
while the zone is bypassed.
Link Camera
AX Security Control Panel User Manual
Figure 2-5 Zone Settings Page
72

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax ds-pw32-hsrAx ds-pw32-hgrAx ds-pw32-hrAx ds-pw32-hs

Table of Contents