The TSSC CD tray opens automatically. Insert the TS3000 System Console
Storage Manager CD, version 10.60.x5.16 (located in the TSSC ship group)
into the TSSC and follow the instructions on the screen to complete the
installation.
4. Locate the firmware and NVSRAM files using the DS Storage Manager GUI.
a. Launch the DS Storage Manager from the TSSC by right-clicking the TSSC
and selecting Browser Functions → Storage Manager GUI Functions →
Launch GUI.
b. Select the Storage Subsystem to be upgraded (identified in step 1 on page
79) by right-clicking the storage and selecting Manage Storage Subsystem.
If prompted to enter a password, enter: ibm2serv. If prompted to change or
set a password, click No. If a Synchronize Controller Clocks dialog is
displayed, click Cancel.
c. In the Manage Storage Subsystem window, select the Advanced button in
the top menu bar.
d. Select Maintenance → Download → Controller Firmware. The Download
Controller Firmware window is displayed. The DS Storage Manager checks
the health of the storage subsystem. This might take several minutes. Any
problems associated with the storage are identified, and you cannot
continue with the upgrade until the problem is resolved. If you cannot
isolate or resolve the error condition, contact your next level of support.
e. In the Controller Firmware panel, click the Select File button. A new
window is displayed.
f. Type the path of the controller firmware and press Enter. The path might be
similar to the following: /home/service/offload/DS4k Storage Manager
v10.60.x5.17 for Windows 32-bit/DS4700. In the same window, select the
FW.DS4700_07602800.dlp file from the Files section.
Note: The storage system firmware is located on the IBM System Storage
ProtecTIER Manager V3.1 DVD under a 10.60.x5.17 for Windows 32-bit
directory, DS4k Storage Manager v10.60.x5.17 for Windows 32-bit. It is used
on the TSSC Linux version as well, and the files are the same.
g. Click the OK button at the bottom of the window. The Download Controller
Firmware window is displayed.
h. In the Download Controller Firmware window, select the Transfer the
NVSRAM file with controller firmware button.
i. Click the Select File button in the NVSRAM section. A new window is
displayed. Type the path of the NVSRAM and press Enter. The path might
be similar to the following: /home/service/offload/DS4k Storage Manager
v10.60.x5.17 for Windows 32-bit/DS4700. In the same window, select the
N1814D47R1060V04.dlp file from the Files section.
Note: The storage system firmware is located on the IBM System Storage
ProtecTIER Manager V3.1 DVD under a 10.60.x5.17 for Windows 32-bit
directory, DS4k Storage Manager v10.60.x5.17 for Windows 32-bit. It is used
on the TSSCLinux version as well, and the files are the same.
j. Click the OK button at the bottom of the window. The Download Controller
Firmware window is displayed.
5. Upgrade the firmware and NVSRAM using the DS Storage Manager . In the
Download Controller Firmware window, click the Transfer button. A version
compatibility window is displayed and you are asked, "Do you want to
continue?" Click Yes. The transfer and activation process takes 15-20 minutes to
complete.
Appendix G. Verifying and upgrading the storage subsystem firmware, NVSRAM, and ESM
81