C004E Power Supply Cooling Fan Motor Malfunction - Konica Minolta Di1611 Service Manual

Hide thumbs Also See for Di1611:
Table of Contents

Advertisement

TROUBLESHOOTING
(4)

C004E Power Supply Cooling Fan Motor Malfunction

<Detection Timing>
Trouble
Code
• The Power Supply Cooling Fan Motor (M4) Lock signal remains HIGH
for a continuous 1-sec. period while the Power Supply Cooling Fan
C004E
Motor Remote signal remains ON (for full-speed rotation) or OFF (for
decelerated-speed rotation).
<Action>
Power Unit Cooling Fan Motor (M4)
Step
Operations
1
Check M4 connectors for proper con-
nection and correct as necessary.
2
Check the fan for possible overload
and correct as necessary.
3
M4 operation check
4
Change PWB-A.
5
Change PU1.
Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
Description
Relevant Electrical Components
Master Board (PWB-A)
Power Supply Unit (PU1)
Ref.
Page
☞ 3-3
3-24
WIRING DIAGRAM
Control signal
(Electrical
Components)
PU1 CN7PU1-1
(REM)
Location
F-12