Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
4.
MAINTENANCE SCHEDULE
4.1
PM Parts List
Paper Take-Up Roll
Paper Separator Roll Assy
Paper Dust Remover
Paper Take-Up/
Transport Sec-
tion
Upper Synchronizing Roller
Lower Synchronizing Roller
Bypass Transport Roller/roll
Mirrors/Lens
IR Section
Scanner Rails/Bushing
Original Glass
PH Section
PH Window
PC Drum
Cleaning Blade
PC Drum Charge Corona Assy
Developer (starter)
Imaging Unit
Ds Collar
Section
Developer Scattering Preven-
tion Plate
Pre-Image Transfer Guide Plate
PC Drum Paper Separator Fin-
ger
Ozone Filter
Image Transfer Roller Assy
Pre-Image Transfer Lower
Image Transfer
Guide Plate
Section
Charge Neutralizing Plate
Fusing Section Fusing Unit
PM Parts
When a malfunction
When a malfunction
When a malfunction
When a malfunction
When a malfunction
When a malfunction
When a malfunction
When a malfunction
When a malfunction
When a malfunction
When a malfunction
When a malfunction
1-7
MAINTENANCE
Cycle (K=1,000)
Clean
Replace
150k
occurs
150k
occurs
40k
occurs
–
occurs
–
occurs
–
occurs
–
occurs
–
occurs
80k
–
–
occurs
40k
occurs
–
40k
–
40k
–
40k
40k
–
40k
–
40k
–
40k
–
–
150k
–
150k
–
occurs
–
occurs
–
150k
Ref.
Page
☞ 1-9
☞ 1-9
☞ 1-11
☞ 1-10
☞ 1-10
☞ 1-11
☞ 1-12
☞ 1-14
☞ 1-12
☞ 1-14
☞ 1-15
☞ 1-18
☞ 1-18
☞ 1-19
☞ 1-19
☞ 1-19
☞ 1-20
☞ 1-18
☞ 1-17
☞ 1-23
☞ 1-23
☞ 1-23
☞ 1-24