Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
<Fusing Unit Interlock Switch Reinstallation Procedure>
1. Fit the switch holder to the Fusing Unit Interlock Switch.
2. Connect the four connectors to the Fusing Unit Interlock Switch Assy.
4. With the right door closed, insert the gauge between the projection of lever and the top
surface of Fusing Unit Interlock Switch, and then secure the switch holder so that the
gap is 0.5 mm.
NOTES
• Use the 0.5 mm thick portion of gauge.
• Insert the gauge between the rear side (projection) of lever and the top surface of Fusing
Unit Interlock Switch.
for Di1611
5. Close the right door, and then use a tester to make sure that the Fusing Unit Interlock
Switch is conducting between 2A and 2B.
6. Open the right door, and then use a tester to make sure that the Fusing Unit Interlock
Switch is not conducting between 2A and 2B.
for Di2011
5. Close the right door, and then use a tester to make sure that the Fusing Unit Interlock
Switch is conducting between 2A and 2B, 3A and 3B.
6. Open the right door, and then use a tester to make sure that the Fusing Unit Interlock
Switch is not conducting between 2A and 2B, 3A and 3B.
NOTE
If there is any abnormality in conducting check, repeat adjustment again from step 4.
3. Temporarily secure the Fusing Unit Interlock
Switch using two screws (to which red paint has
been applied).
4035D131AA
Projection
4035D541AA
1-55
Di1611
Di2011
MAINTENANCE
4035D540AA
4035D539AA