TROUBLESHOOTING
(2)
C0044 ADF Cooling Fan Failure
(When the optional Duplexing Document Feeder AFR-19 is mounted)
<Detection Timing>
Trouble
Code
• The ADF Fan Motor Lock signal remains set to H for a set period of
C0044
time while the EDH Fan Motor is turning.
<Action>
Cooling Fan Motor (M3-ADF)
Step
Operations
1
Check the motor connectors for
paper connection, and correct as
necessary.
2
Check the fan for possible overload,
and correct as necessary.
3
M3-ADF operation check.
4
Replace PBA-CONT.
Di1611/Di2011 FIELD SERVICE Ver.1.0 Mar. 2004
Description
Relevant Electrical Components
Main Control Board (PBA-CONT)
Ref.
Page
☞ 3-3
3-22
WIRING DIAGRAM
Control signal
Components)
PBA-CONT
E-5 (AFR-19)
CN9CONT-2 (REM)
Location