Festo CPX DE Series Manual page 68

Digital i/o modules, sub-bases and pneumatic interfaces
Hide thumbs Also See for CPX DE Series:
Table of Contents

Advertisement

2. Digital CPX input modules
Input module type CPX−8DE−D with sub−base CPX−AB−2−HARX2−4POL
Sub−base
Tab. 2/17: Pin assignment of I−module type CPX−8DE−D with sub−base
CPX−AB−4−HARX2−4POL
2−20
Pin assignment CPX−8DE−D with sub−base
CPX−AB−4−HARX2−4POL
On this sub−base only the sensor supplies for the inputs Ix,
Ix+2, Ix+4 and Ix+6 are available. These supplies are used in
pairs by the inputs Ix/Ix+1, Ix+2/Ix+3, Ix+4/Ix+5 and
Ix+6/Ix+7. The diagnostic messages are therefore only for the
inputs Ix, Ix+2, Ix+4 and Ix+6. The inputs Ix+1, Ix+3, Ix+5 and
Ix+7 do not generate a diagnostic message.
Pin assignment X1, X2
Socket X1:
4
1
1: 24 V
2: Ix+1
3
2
3: 0 V
X1
4: Ix
Socket X2:
X2
1: 24 V
2
3
2: Ix+3
3: 0 V
4: Ix+2
1
4
Ix = Input x
FE = functional earth
LED
Pin assignment X3, X4
4
SENx
1
3
SENx
0
2
SENx+2
3
SENx+2
2
1
Socket X3:
1
1: 24 V
SENx+4
2: Ix+5
2
3: 0 V
SENx+4
X3
4: Ix+4
Socket X4:
X4
1: 24 V
3
SENx+6
2: Ix+7
3: 0 V
SENx+6
4: Ix+6
4
Festo P.BE−CPX−EA−EN en 0804g
LED
5
4
7
6

Hide quick links: