3. Digital CPX output modules
Module parameters: Behaviour after short circuit/overload
Function no.
4828 + m * 64 + 1
Description
Determines after a short circuit of the outputs whether the power is to remain
switched off or whether it is to be switched on again automatically.
Behaviour after short circuit/overload
Bit
Description
1
Short circuit/overload at the outputs (SCO)
Values
0 = V
1 = V
Note
With the setting V
reset before the power can be restored. Check which setting is necessary for
reliable operation of your system.
Detailed description under Diagnosis, Tab. 3/23.
Tab. 3/19: Behaviour after short circuit/overload
Module parameters: Fail safe channel x
Function no.
Access to these module parameters is made via protocol−specific functions
(see the manual for the bus node).
Description
Fault mode channel x: Hold last state
Fault state channel x: Set output
Note
With the aid of the so−called Fail safe parameterizing, you can specify the signal
status which the outputs are to assume in the event of field bus communication
faults (see also CPX system manual).
Tab. 3/20: Fail safe channel x (channel−specific)
Festo P.BE−CPX−EA−EN en 0804g
remains switched off (presetting)
OUT
switch on again
OUT
remains switched off" the relevant output must be set/
OUT
Fault state (presetting)
Reset output (presetting)
m = module number (0
47)
[Behaviour after]
[Behaviour after SCO]
[Leave switched off ]
[Resume]
3−23