A. Technical appendix
Technical specifications
Short circuit protection
Discrete fusing of the outputs
Voltage drop at output
Output delay with ohmic load
signal change 0" to 1"
signal change 1" to 0"
Parallel switching of outputs for
increased performance
Protection against reverse voltage
Limiting the inductive switch−off
voltage of connected coils/solenoid
valves
Electrical isolation...
between the channels
between the operating voltage
supply for the electronics/sensors
(V
) and the load voltage for the
EL/SEN
outputs (V
)
OUT
Isolation
Module code [type code] (CPX−specific)
Module identification (Handheld)
A−8
CPX−4DA
CPX−8DA
yes (electronic),
yes (electronic),
response
response
threshold ,1 A
threshold , 0.5 A
none
none
1 V
. 200 s
. 200 s
yes, max. 4 outputs of the same
module:
O0
O3
O0 O3/O4 O7
max. V
OUT
typ. −16 V
none
yes, with power supply via manifold sub−base type:
CPX−GE−EV−Z (M18)
CPX−GE−EV−S−7/8−5POL
CPX−GE−EV−Z−7/8−5POL
CPX−M−GE−EV−S−7/8−5POL
CPX−M−GE−EV−Z−7/8−5POL
CPX−GE−EV−Z−7/8−4POL
tested with 500 V DC
3
6
4DO
8DO
CPX−8DA−H
yes (electronic),
response
threshold see
Fig. A/1
cutout fuse (4 A,
slow−blowing)
1 V
. 200 s
. 200 s
not permitted
17
8DO−H
Festo P.BE−CPX−EA−E N en 0804g