Festo CPX DE Series Manual page 35

Digital i/o modules, sub-bases and pneumatic interfaces
Hide thumbs Also See for CPX DE Series:
Table of Contents

Advertisement

1. Overview and sub−bases for CPX I/O modules
Festo P.BE−CPX−EA−EN en 0804g
Sub−bases CPX−AB−8−M8−3POL and −4POL
Please note
In order that the completely fitted modules with sub−bases
CPX−AB−8−M8−3POL and −4POL comply with protection
class IP65/IP67:
use plugs and cables from the Festo range for con
·
necting the sensors and actuators (see section B.3).
Tighten the union nuts of the plugs at first by hand.
·
Seal unused sockets with protective caps type ISK−M8
·
(Accessories).
Sub−base CPX−AB−8−KL−4POL
The completely fitted sub−base CPX−AB−8−KL−4POL complies
with protection class IP20.
Specifications of the cable terminals
Cable cross−sectional area:
Max. current:
Insulation removed:
Permitted copper conductors
Single wire, multi−wire, fine wire,
also with tin−plated individual cores
Fine wire strands compressed
Fine wire with core end sleeves
(sealed against gas, crimped on)
Fine wire with pin cable socket
(sealed against gas, crimped on)
*)
If necessary, use next smaller cross−sectional area.
2
0.08
1.5 mm
see section A.1
5
6 mm
*)
*)
1−17