A. Technical appendix
Technical specifications
Digital outputs
Rated load voltage
Version
Protection against incorrect polarity
Output current per channel
Short circuit protection
Voltage drop at output
Output delay with ohmic load
Parallel switching of outputs for increased performance
Protection against reverse voltage
Limiting the inductive switch−off voltage of connected coils/
solenoid valves
Electrical isolation of the outputs...
between the channels
between the operating voltage supply for the electronics/
sensors (V
) and the load voltage for the outputs
EL/SEN
(V
)
OUT
Isolation
Module code [type code] (CPX−specific)
Module identification (Handheld)
Festo P.BE−CPX−EA−E N en 0804g
signal change 0" to 1"
signal change 1" to 0"
CPX−8DE−8DA
8 outputs as per IEC 1131, 24 V
V
OUT
positive logic (PNP)
yes
max. 0.5 A (12 W lamp load)
yes (electronic), response
threshold , 0.5 A
1 V
. 200 s
. 200 s
yes, max. 4 outputs (O0
O4
O7) of the same module
max. V
OUT
typ. −16 V
none
yes, with power supply via manifold
sub−base type:
CPX−GE−EV−Z (M18)
CPX−GE−EV−S−7/8−5POL
CPX−GE−EV−Z−7/8−5POL
CPX−M−GE−EV−S−7/8−5POL
CPX−M−GE−EV−Z−7/8−5POL
CPX−GE−EV−Z−7/8−4POL
tested with 500 V DC
4
8DI/8DO
O3 or