Configuring/address space

4.1

Configuring

Introduction
You can configure the SIMATIC ET 200SP TM ECC PL ST technology module with the
configuration software or use the configuration software to assign parameters.
System environment
You can use the technology module in the following system environments:
Table 4- 1
Possible applications of the technology module with PROFINET I/O
Applications
Distributed operation in an
S7-1500 system
Centralized or distributed
operation in an ET 200SP
system
Hardware Support Package (HSP)
If you do not find the technology module SIMATIC ET 200SP TM ECC PL ST in the
hardware catalog of the TIA Portal, you have to install the corresponding HSP file (HSP0261
ET200SP ECC PL).
The Hardware Support Package (HSP) is available as download
(http://support.automation.siemens.com/WW/view/en/72341852) on the Internet.
Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)
Manual, 07/2019, A5E43919893B-AA
Required components
S7-1500 Automation
system
ET 200SP Distributed I/O
System
Technology module
SIMATIC ET 200SP
TM ECC PL ST
ET 200SP automation
system
Technology module
SIMATIC ET 200SP
TM ECC PL ST
Configuration software
STEP 7 (TIA Portal):
Device configuration and
parameter settings with the
hardware configuration
(HWCN)
STEP 7 (TIA Portal):
Device configuration and
parameter settings with the
hardware configuration
(HWCN)
4
In your program
Direct access to the control
and feedback interface
(Page 37) of the technology
module SIMATIC ET 200SP
TM ECC PL ST in the I/O
data
Access only via the function
block DIN_70121
Access only via the function
block DIN_70121
35