Din_70121 Parameter; Udt_Charger_In - Siemens SIMATIC ET 200SP Manual

Technology module tm ecc pl st
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

● Hardware status requested by the function block:
out.setpoints.hwState
● SW state of the function block
out.swState
5.5

DIN_70121 parameter

All parameters are created in form of the UDTs (User defined Data Types).
The "in" input is mapped in form of the UDT "UDT_Charger_In".
The "out" output is mapped in form of the UDT "UDT_Charger_Out".
5.5.1

UDT_Charger_In

The UDT_Charger_In has the following structure:
Table 5- 2
List of input parameters for the UDT_Charger_In
Parameter
ackErrors
enable
evseCfg
hw_id
hwError
values
Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)
Manual, 07/2019, A5E43919893B-AA
Data type
Description
Bool
Error acknowledgment
In the "True" state, all pending errors are acknowledged.
Bool
Charging outlet enable (True = yes, False = no)
If this input is set to "False", an ongoing charging process is canceled and
the frequency converter is shut down in a controlled manner. Subsequently
the CP output signal in the module is set to -12 V.
If the Enable input is set to "True", the CP output signal changes to +12 V.
UDT_Charger_
Input parameter for the configuration of the charging station
EvseCfg
HW_IO
Hardware ID of the technology module SIMATIC ET 200SP TM ECC PL
ST for the determination of the offset of the process image of the in-
puts/outputs.
If an invalid HW ID is entered, a corresponding error bit at the output is set
to "True" (Error messages (Page 66)).
Byte
Pending HW errors / warnings of the charging station:
Bit 0: Insulation monitor "warning"
Bit 1: Insulation monitor "Error"
Bit 2: An emergency-off of the charging station has taken place (for
example by pressing the emergency-off button)
If Bit 1 or Bit 2 is set to "True", the converter is ramped down in a con-
trolled manner if possible. The CP output level is set to "-12V".
UDT_Charger_
Currently pending parameters of the charging station that are relevant for
Values
the charging process.