Programming
5.6 Error messages
33
No
Timeout during status change of the
CP from B to C
34
No
Timeout during state change of the CP
from C to B
35
No
Unexpected change of the CP to B
36
No
Unexpected change of the CP to C
37
No
SLAC error
38
No
Timeout for V2G message
39 ...
-
Reserved
47
48
No
Messages of the vehicle
These messages are only passed
49
No
through and have no direct influence on
50
No
the currently pending charging pro-
51
No
cesses.
52
No
(For further information, refer to the
DIN SPEC 70121)
53
No
54
No
55
No
56
No
57
No
58
No
59...
-
Reserved
63
70
The charging protocol provides for a CPU transition from
State B to State C at this point. This bit is set if the transi-
tion is not made within 1.5 s.
The charging protocol provides for a CPU transition from
State C to State B at this point. This bit is set if the transi-
tion is not made within 1.5 s.
The CP is in State B. This is not allowed in the current
status within the charging procedure.
The CP is in State B. This is not allowed in the current
state within the charging procedure.
Error during the PLC connection setup (SLAC process).
Vehicle does not send message packet within the pre-
scribed time (e.g. 60 s).
-
FAILED_RESSTemperatureInhibit
FAILED_EVShiftPosition
FAILED_ChargerConnectorLockFault
FAILED_EVRESSMalfunction
FAILED_ChargingCurrentdifferential
FAILED_ChargingVoltageOutOfRange
Reserved A
Reserved B
Reserved C
FAILED_ChargingSystemIncompatibility
NoData
-
Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)
Manual, 07/2019, A5E43919893B-AA