Udt_Charger_Out - Siemens SIMATIC ET 200SP Manual

Technology module tm ecc pl st
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Programming
5.5 DIN_70121 parameter
5.5.4

UDT_Charger_Out

The UDT_Charger_Out has the following structure:
Table 5- 5
List of input parameters to the UDT_Charger_Out
Parameter
ev
pilotState
60
Data type
Description
UDT_Charger_
Information with regard to the vehicle
Ev
USINT
Charging state
At this output the state is output according to IEC 61851-1.
0: State A1 (100% PWM)
Charging station not ready for charging / Vehicle not connected
(State according to IEC 61851-1)
1: State B1 (100% PWM)
Charging station not ready for charging / Vehicle not ready for charging
(State according to IEC 61851-1)
2: State B2 (5% PWM)
Charging station ready for charging / Vehicle not ready for charging
(State according to IEC 61851-1)
3: State C1 (100% PWM)
Charging station not ready for charging / Vehicle ready for charging
(State according to IEC 61851-1)
4: State C2 (5% PWM)
Charging station ready for charging / Vehicle ready for charging
(State according to IEC 61851-1)
5: State D1 (100% PWM)
Charging station not ready for charging / Vehicle ready for charging /
Ventilation required
(State according to IEC 61851-1)
6: State D2 (5% PWM)
Charging station ready for charging / Vehicle ready for charging / Venti-
lation required
(State according to IEC 61851-1)
7: State E (100% PWM)
e.g. if charging station is current-free or short-circuit between CP and
protective conductor
(State according to IEC 61851-1)
8: State F
Charging station not ready for charging
e.g. Error occurred or charging station in maintenance - charging outlet
locked
(State according to IEC 61851-1)
9: Invalid state
CP current outside the permitted range
Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)