Siemens SIMATIC ET 200SP Manual page 57

Technology module tm ecc pl st
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

maxExtVoltageInVolt
maxPowerInkW
maxSwitchTimeBreaker
maxSwitchTimeHwState
maxTimeInvalidParamsOr-
RampCharge
maxTimeRampUpDown
maxVoltageInVolt
minCurrentInAmpere
minVoltageInVolt
peakCurrentRippleInAm-
pere
Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)
Manual, 07/2019, A5E43919893B-AA
UInt
The maximum permitted voltage on the cable (external voltage check)
before the cable check (see chapter Checking the de-energized state
(Page 44)).
If exceeded, a corresponding error bit at the output is set to "True" (see
section Error messages (Page 66))
UInt
Maximum available power (in kW) of the charge column.
Time
The maximum time has been exceeded in which the feedback signal of the
DC/Precharge or shunt breaker has to be performed.
If this time is exceeded, a corresponding error bit at the output is set to
"True" (see Error messages (Page 66)).
This time must be greater than "0 ms"; otherwise the error message bit 1
(parameterization error) is set.
Time
Maximum time that is available to switch from one HW state to next re-
quired state (see chapter HW states (Page 51))
If this time is exceeded, a corresponding error bit at the output is set to
"True" (see section Error messages (Page 66)).
This time must be greater than "0 ms"; otherwise the error message bit 1
(parameterization error) is set.
Time
The maximum time in which the charging column must follow the specifica-
tions of the vehicle (target voltage, target current).
If this time is exceeded, a corresponding error bit at the output is set to
"True" (see section Error messages (Page 66)).
This time must be greater than or equal to the value of "maxTi-
meRampUpDown"; otherwise the error message bit 1 (parameterization) is
set.
Time
The maximum time in which the converter must have reached the desired
value (charging voltage or charging current). Affects all charging phases
except the "PreCharge" and "CurrentDemand" phase.
If this time is exceeded, a corresponding error bit at the output is set to
"True" (see section Error messages (Page 66)).
This time must be greater than "0 ms"; otherwise the error message bit 1
(parameterization error) is set.
The time must be less than or equal to the time parameterized under
"maxTimeInvalidParamsOrRampCharge".
UInt
The maximum charging voltage (in V) of the charging column.
This voltage must be greater than the value of "minVoltageInVolt"; other-
wise the error message bit 1 (parameterization error) is set.
UInt
The minimum charging current (in A) of the charging column.
This current must be less than the value of "maxCurrentInAmpere"; other-
wise the error message bit 1 (parameterization error) is set.
UInt
The minimum voltage (in V) of the charge column.
This voltage must be less than the value of "maxVoltageInVolt"; otherwise
the error message bit 1 (parameterization error) is set.
UInt
Maximum current ripple (in A) on the charging current.
Programming