Configuring/address space

4.2 Reaction to CPU STOP

4.2
Reaction to CPU STOP
At CPU STOP an active charging process is terminated immediately. This means the PWM
signal on the CP switches to "-12 V" (EVSE status not available).
Breakdowns in communication, such as an interruption of the PROFINET connection, are
treated as CPU STOPs.
4.3

Required I/O address space

Address space of the technology module
Table 4- 2
Scope
4.4

Parameter

Parameter
You specify the properties of the technology module using various parameters. These can
be assigned via the HSP. Depending on the settings, not all parameters are available. You
cannot change the parameter assignment in the user program.
You have the following options for setting the parameters of the module:
Table 4- 3
Parameter settings using the ...
Hardware configuration in
STEP 7 with HSP file
36
Scope of the I/O addresses of the technology module SIMATIC ET 200SP TM ECC PL
ST
Inputs
32 bytes
Parameter assignment options
Basic procedure
1. Install the corresponding HSP file.
The module is contained in the hardware catalog under "Dis-
tributed IO devices \ ET 200SP \ Technology modules \ Charg-
ing \ TM ECC PL 12V ST".
2. Set the device configuration and the parameters in the hard-
ware configuration.
3. Download the parameter assignment to the module.
Outputs
32 bytes
Technology module TM ECC PL ST (6FE1242-6TM20-0BB1)
Manual, 07/2019, A5E43919893B-AA