Programming
5.5 DIN_70121 parameter
5.5.2

UDT_Charger_EvseCfg

The UDT_Charger_EvseCfg has the following structure:
Table 5- 3
List of input parameters for the UDT_Charger_EvseCfg
Parameter
cableCheckCurrentInAm-
pere
dcbrkIsUsed
emcInAmpere
emvInVolt
evseId
evseIdLength
extVoltageCheckIsSup-
ported
maxCableCheckLeakCur-
rentInAmpere
maxCurrentInAmpere
54
Data type
Description
UInt
Current setpoint (in A) during the "Cable check" phase.
This parameter is relevant for such converters that are required for the
start of a minimum current value.
This current must be greater than the value of "maxCableLeakCurrentIn-
Ampere"; otherwise the error message bit 1 (parameterization error) is set.
(see chapter on Cable Check (Page 45))
Bool
Monitoring of the feedback from the "DC breaker" and control of the corre-
sponding output.
(True = yes, False = no)
(see chapter on Protective circuit of the frequency converter (Page 41))
UInt
Maximum absolute current tolerance (in A) of the used measuring instru-
ment.
(relevant in Cable Check phase and when terminating the charging pro-
cess)
UInt
Maximum absolute voltage tolerance (in V) of the used measuring instru-
ment.
(relevant in External Voltage Check, Cable Check, PreCharge phase and
termination of the charging process)
Array [0..31] of
Unique ID of the charge column. The structure of the ID is defined in the
Byte
DIN SPEC 91286.
Details of the structure can also be found in the DIN SPEC 70121.
USINT
Length of the evseld address in bytes
If this value is greater than "32", the error message bit 1 (parameterization
error) is set.
Bool
Activation of the check of the applied voltage before the pending phase
"Cable check". (True = Yes, False = No)
(see the chapter on Checking the de-energized state (Page 44))
The voltage "maxExtVoltageInVolt" must be less than or equal to the value
of "maxVoltageInVolt"; otherwise the error message bit 1 (parameterization
error) is set (see section Error messages (Page 66)).
UInt
The maximum DC leakage current that is allowed during the cable check
(see chapter Cable check (Page 45)).
If the leakage current is greater, a corresponding error bit at the output is
set to "True" (see section Error messages (Page 66)).
This current must be less than or equal to the value of "maxCurrentIn-
Ampere"; otherwise the error message bit 1 (parameterization error) is set.
UInt
The currently available maximum current which can be delivered by the
charge column.
This current must be greater than the value of "minCurrentInAmpere";
otherwise the error message bit 1 (parameterization error) is set.