Siemens SIMATIC ET 200SP Manual page 70

Technology module tm ecc pl st
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Programming
5.6 Error messages
10
Yes
Current Demand
11
Yes
12
Yes
Termination of the charging process
13
Yes
Timeout error
14
Yes
15
Yes
16
Yes
68
Range errors current, voltage, power
The "out.setpoints.voltageInVolt" voltage required by
the vehicle lies outside the valid range.
The "out.setpoints.currentInAmpere" current required
by the vehicle lies outside the valid range.
The output voltage of the frequency converter
"in.values.voltageInVolt" lies outside the valid range.
The output voltage of the frequency converter
"in.values.currentInAmpere" lies outside the valid
range.
The maximum charging capacity is exceeded.
If possible, the frequency converter is shut down in a
controlled manner.
Invalid parameters
The target values required by the vehicle lie outside
the permitted range.
The frequency converter is ramped down in a controlled
manner.
The current could not be ramped down.
Possible causes of the fault:
Frequency converter errors
Time "in.evseCfg.maxTimeRampUpDown" set too low
Maximum charging current set too small when open-
ing the "in.evseCfg.stopChargingCurrentInAmpere"
breaker
If possible, the frequency converter is shut down in a
controlled manner.
The PreCharge breaker has not opened or closed within
the response time defined in
"in.evseCfg.maxSwitchTimeBreaker".
The frequency converter is ramped down in a controlled
manner.
The DC breaker has not closed or opened within the re-
sponse time defined in
"in.evseCfg.maxSwitchTimeBreaker".
The frequency converter is ramped down in a controlled
manner.
The Shunt breaker has not opened or closed within the
reaction time defined in
"in.evseCfg.maxSwitchTimeBreaker".
The frequency converter is ramped down in a controlled
manner.
The frequency converter does not reach the correspond-
ing "out.setpoints.hwState" HW state within the response
time defined in "in.evseCfg.maxSwitchTimeHwState".
If possible, the frequency converter is shut down in a
controlled manner.